Computational Assessment of Unsteady Flow Effects on Magnetic Nanoparticle Targeting Efficiency in a Magnetic Stented Carotid Bifurcation Artery.

Rodward L Hewlin, Michael Smith, John P Kizito

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular engineering and technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Rodward L HewlinDepartment of Engineering Technology, University of North Carolina at Charlotte, Charlotte, USA. rhewlin@uncc.edu.ORCID 0000-0002-1213-823X
Michael SmithDepartment of Engineering Technology, University of North Carolina at Charlotte, Charlotte, USA.ORCID 0000-0003-2904-718X
John P KizitoDepartment of Mechanical Engineering, North Carolina Agricultural and Technical State University, Greensboro, USA.
University of North Carolina at Charlotte · USNorth Carolina Agricultural and Technical State University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWorldwide, cardiovascular disease is the leading cause of hospitalization and death. Recently, the use of magnetizable nanoparticles for medical drug delivery has received much attention for potential treatment of both cancer and cardiovascular disease. However, proper understanding of the interacting magnetic field forces and the hydrodynamics of blood flow is needed for effective implementation. This paper presents the computational results of simulated implant assisted medical drug targeting (IA-MDT) via induced magnetism intended for administering patient specific doses of therapeutic agents to specific sites in the cardiovascular system. The drug delivery scheme presented in this paper functions via placement of a faintly magnetizable stent at a diseased location in the carotid artery, followed by delivery of magnetically susceptible drug carriers guided by the local magnetic field. Using this method, the magnetic stent can apply high localized magnetic field gradients within the diseased artery, while only exposing the neighboring tissues, arteries, and organs to a modest magnetic field. The localized field gradients also produce the forces needed to attract and hold drug-containing magnetic nanoparticles at the implant site for delivering therapeutic agents to treat in-stent restenosis.

methodsThe multi-physics computational model used in this work is from our previous work and has been slightly modified for the case scenario presented in this paper. The computational model is used to analyze pulsatile blood flow, particle motion, and particle capture efficiency in a magnetic stented region using the magnetic properties of magnetite (Fe

resultsThe computational simulations demonstrate that the greatest particle capture efficiency results for particle diameters within the micron range of 0.7-4 µm, specifically in regions where flow separation and vortices are at a minimum. Similar to our previous work (which did not involve the use of a magnetic stent), it was also observed that the capture efficiency of particles decreases substantially with particle diameter, especially in the superparamagnetic regime. Contrary to our previous work, using a magnetic stent tripled the capture efficiency of superparamagnetic particles. The highest capture efficiency observed for superparamagnetic particles was 78% with an 8 T magnetic field strength and 65% with a 2 T magnetic field strength when analyzing 100 nm particles. For 10 nm particles and an 8 T magnetic field strength, the particle capture efficiency was 55% and for a 2 T magnetic field strength the particle capture efficiency was observed to be 43%. Furthermore, it was found that larger magnetic field strengths, large particle diameter sizes (1 µm and above), and slower blood flow velocity improves the particle capture efficiency. The distribution of captured particles on the vessel wall along the axial and azimuthal directions is also discussed. Results for captured particles on the vessel wall along the axial flow direction showed that the particle density decreased along the axial direction, especially after the stented region. For the entrance section of the stented region, the captured particle density distribution along the axial direction is large, corresponding to the center-symmetrical distribution of the magnetic force in that section.

conclusionThe simulation results presented in this work have shown to yield favorable capture efficiencies for micron range particles and superparamagnetic particles using magnetized implants such as the stent discussed in this work. The results presented in this work justify further investigation of MDT as a treatment technique for cardiovascular disease.

Indexed as

Cardiovascular DiseasesMagnetite NanoparticlesCarotid ArteriesComputer SimulationDrug Delivery SystemsHumansMagnetic FieldsMagnetite NanoparticlesCapture efficiencyCardiovascular diseaseCarotid arteryDrug deliveryEulerianLagrangianMagnetic drug targetingMagnetitePatient-specificPulsatile flowStent

Identifiers

PMID37723333
OpenAlexW4386824117

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.