Validation of deep learning-based CT image reconstruction for treatment planning.

Keisuke Yasui, Yasunori Saito, Azumi Ito, Momoka Douwaki, Shuta Ogawa, Yuri Kasugai, Hiromu Ooe, Yuya Nagake, Naoki Hayashi

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Machine Learning and Deep Learning Applications in Magnetic Particle Imaging.Journal of magnetic resonance imaging : JMRI · 2025
    Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Keisuke YasuiDivision of Medical Physics, School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan. k-yasui@fujita-hu.ac.jp.
Yasunori SaitoDepartment of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan.
Azumi ItoFaculty of Radiological Technology, School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
Momoka DouwakiDepartment of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan.
Shuta OgawaDepartment of Radiology, Fujita Health University Hospital, Toyoake, Aichi, Japan.
Yuri KasugaiFaculty of Radiological Technology, School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
Hiromu OoeFaculty of Radiological Technology, School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
Yuya NagakeFaculty of Radiological Technology, School of Medical Sciences, Fujita Health University, Toyoake, Aichi, Japan.
Naoki HayashiDivision of Medical Physics, School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-Cho, Toyoake, Aichi, 470-1192, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Deep learning-based CT image reconstruction (DLR) is a state-of-the-art method for obtaining CT images. This study aimed to evaluate the usefulness of DLR in radiotherapy. Data were acquired using a large-bore CT system and an electron density phantom for radiotherapy. We compared the CT values, image noise, and CT value-to-electron density conversion table of DLR and hybrid iterative reconstruction (H-IR) for various doses. Further, we evaluated three DLR reconstruction strength patterns (Mild, Standard, and Strong). The variations of CT values of DLR and H-IR were large at low doses, and the difference in average CT values was insignificant with less than 10 HU at doses of 100 mAs and above. DLR showed less change in CT values and smaller image noise relative to H-IR. The noise-reduction effect was particularly large in the low-dose region. The difference in image noise between DLR Mild and Standard/Strong was large, suggesting the usefulness of reconstruction intensities higher than Mild. DLR showed stable CT values and low image noise for various materials, even at low doses; particularly for Standard or Strong, the reduction in image noise was significant. These findings indicate the usefulness of DLR in treatment planning using large-bore CT systems.

Indexed as

Deep LearningRadiation OncologyImage Processing, Computer-AssistedPhantoms, ImagingTomography, X-Ray Computed

Identifiers

PMID37723226
PMCPMC10507027

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.