ArticleJournal of applied clinical medical physics2024
Dosimetric impact of MLC positional errors on dose distribution in IMRT.
Article in Journal of applied clinical medical physics, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed.
- Complementary roles of GPU-accelerated Monte Carlo and ArcCHECK in TomoTherapy quality assurance.Physical and engineering sciences in medicine · 2026Article
- Determining optimal transit dosimetry gamma parameter values for the detection of failure modes using receiver operating curve analysis.Journal of applied clinical medical physics · 2026Article
- Comparison of log file-based and measurement-based QA for detecting MLC positional errors and evaluating dosimetric impacts of MLC defects.Journal of applied clinical medical physics · 2025Article
- A pathway away from measurement-based patient-specific QA: A review of contemporary quality assurance for external-beam radiotherapy sub-systems.Journal of applied clinical medical physics · 2025Review
- A novel protocol for parametrization of a beam model for small stereotactic beams.Journal of applied clinical medical physics · 2025Article
- The impact of plan complexity on dose delivery deviations resulting from multileaf collimator positioning errors in volumetric modulated arc therapy.The British journal of radiology · 2025Article
- Dosimetric impact of MLC positional errors on dose distribution in IMRT.Journal of applied clinical medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Optimizing the positional accuracy of multileaf collimators (MLC) for radiotherapy is important for dose accuracy and for reducing doses delivered to normal tissues. This study investigates dose sensitivity variations and complexity metrics of MLC positional error in volumetric modulated arc therapy and determines the acceptable ranges of MLC positional accuracy in several clinical situations. Treatment plans were generated for four treatment sites (prostate cancer, lung cancer, spinal, and brain metastases) using different treatment planning systems (TPSs) and fraction sizes. Each treatment plan introduced 0.25-2.0 mm systematic or random MLC leaf bank errors. The generalized equivalent uniform dose (gEUD) sensitivity and complexity metrics (MU/Gy and plan irregularity) were calculated, and the correlation coefficients were assessed. Furthermore, the required tolerances for MLC positional accuracy control were calculated. The gEUD sensitivity showed the highest dependence of systematic positional error on the treatment site, followed by TPS and fraction size. The gEUD sensitivities were 6.7, 4.5, 2.5, and 1.7%/mm for Monaco and 8.9, 6.2, 3.4, and 2.3%/mm (spinal metastasis, lung cancer, prostate cancer, and brain metastasis, respectively) for RayStation. The gEUD sensitivity was strongly correlated with the complexity metrics (r = 0.88-0.93). The minimum allowable positional error for MLC was 0.63, 0.34, 1.02, and 0.28 mm (prostate, lung, brain, and spinal metastasis, respectively). The acceptable range of MLC positional accuracy depends on the treatment site, and an appropriate tolerance should be set for each treatment site with reference to the complexity metric. It is expected to enable easier and more detailed MLC positional accuracy control than before by reducing dose errors to patients at the treatment planning stage and by controlling MLC quality based on complexity metrics, such as MU/Gy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials