ArticleTurkish journal of chemistry2023
Removal of amoxicillin via chromatographic monolithic columns: comparison between batch and continuous fixed bed.
Article in Turkish journal of chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A novel p-n junction UiO-66/AgInSTurkish journal of chemistry · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study presented a hydrophobic interaction-based poly(HEMA-MATrp) monolithic chromatographic column (MCC) to remove amoxicillin from aqueous solutions. In addition to their porous structure, monolithic-filled columns offer superior properties without loss of performance, which is one of the points that make them unique. The specific surface area of the monolithic column synthesized by the bulk polymerization of 2-hydroxyethyl methacrylate and N-Methacryloyl-L-tryptophan. Also, poly(HEMA-MATrp) MCC has been characterized via FTIR, SEM, and elemental analysis. According to BET analysis, the specific surface area of the poly(HEMA-MATrp) monolithic chromatographic column (MCC) is 14.2 mg/g. The adsorption and desorption of amoxicillin in an aqueous solution were investigated comparatively in both continuous fixed bed and batch adsorption. The highest adsorption value of amoxicillin was determined at pH 7 in the presence of PBS as 62.11 mg/g. The appropriate adsorption isotherm for the adsorption of amoxicillin was Langmuir, and the reaction kinetics was pseudo-second-order. No significant loss was observed for the adsorption capacity of poly(HEMA-MATrp) MCC after the 5 cycles of adsorption-desorption studies. Also, the loss for the adsorption capacity of the monolithic column is just %5.2 after 6-month storage, proving the reusability and storability of the monolithic column.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.