Evidence map›Paper›PMID 37719510›Full record

ArticleCureus2023

Evaluation of Unicortical Locking Screw Placement for Torsional Loads in Distal Radius Fractures: A Biomechanical Study in Cadavers.

Ali T Pehlivan, Bekir E Kilinc, Yunus Oc, Mustafa Vezirhuyuk, Fatih Yamak, Ergun Bozdag

Abstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ali T PehlivanOrthopaedics and Traumatology, Denizli Private Health Hospital, Istanbul, TUR.
Bekir E KilincOrthopaedic Surgery and Traumatology, University of Health Sciences, Fatih Sultan Mehmet Training and Research Hospital, Istanbul, TUR.
Yunus OcOrthopaedics and Traumatology, Beykent University, Istanbul, TUR.
Mustafa VezirhuyukOrthopaedic Surgery, Sanliurfa Training and Research Hospital, Sanliurfa, TUR.
Fatih YamakFaculty of Mechanical Engineering, Strength of Materials and Biomechanics Laboratory, Istanbul Technical University, Istanbul, TUR.
Ergun BozdagFaculty of Mechanical Engineering, Strength of Materials and Biomechanics Laboratory, Istanbul Technical University, Istanbul, TUR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background We aimed to compare bio-mechanical outcomes of short-length 75%-length uni-cortical screw (SL75UCS) and full-length 100%-length screws (FL100S) under axial compression (AXC) and torsional compression (TRC) in cadaveric distal radius volar plate model. Methodology A total of 20 wrists from 10 fresh frozen cadavers were included. A 2.5 mm titanium alloy distal radius anatomical plate was placed to the distal radii in full anatomical position, just proximal to the watershed line. Three bi-cortical screws to the shaft of the radius, followed by uni-cortical drilling for distal screwing were placed. Measurement by pulling the drill once it reached the opposite cortex was applied. We selected the screw lengths such that they corresponded to the SL75UCS. In the same configuration for each of the cadavers, we delivered six screws from distal radius holes of the anatomical plate. An oscillating handsaw was used to create an extra-articular distal radius fracture model (AO 23-A3.2). We created a dorsal AP model by performing a 1-cm wedge osteotomy from the dorsal aspect. Complete separation of the volar cortex was achieved. Potting was performed by embedding the shaft of the prepared radius into the polyurethane medium. We placed aluminum apparatus into the distal end to ensure applying of AXC and TRC in bio-mechanistic tests. Results No statistically significant difference of stiffness between the SL75UCS and FL100S both under AXC (p=0.88) and TRC (p=0.82). SL75UCS and FL100S groups did not differ in elastic limit under AXC (p=0.71) and TRC (p=0.71). Maximal force on SL75UCS and FL100S groups were also similar under both AXC (p=0.71) and TRC (p=0.50). Conclusions Our study findings suggest that drilling the dorsal cortex may not be necessary in the management of distal radius fractures. Instead, utilizing SL75UCS could serve as a viable alternative. This approach offers potential advantages in reducing the risk of extensor tendon complications associated with drilling or screw protrusion. It is a safe method under torsional load to avoid drilling of the dorsal cortex and SL75UCS could be performed in order to prevent from extensor tendon complications secondary to drilling or screw protrusion.

Indexed as

bi-cortical screwdistal radius fracturetorsional loaduni-cortical screwvolar plate

Identifiers

PMID37719510
PMCPMC10501418

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.