Evidence map›Paper›PMID 37712737›Full record

ArticleCritical care science2023

Estimated continuous cardiac output based on pulse wave transit time in critically ill children: a report of two cases.

Humberto Magalhães Silva, Raisa Sanches Uzun, Isabel de Siqueira Ferraz, Marcelo Barciela Brandão, Tiago Henrique de Souza

Abstract readCase ReportsLetter
In one paragraph

Article in Critical care science, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Observational
  2. Reliability and benefit of estimated continuous cardiac output measurement using shunt-side SpOTherapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2025
    Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Humberto Magalhães SilvaPediatric Intensive Care Unit, Department of Pediatrics, Hospital de Clínicas, Universidade Estadual de Campinas - Campinas (SP), Brazil.ORCID 0009-0009-9671-7009
Raisa Sanches UzunPediatric Intensive Care Unit, Department of Pediatrics, Hospital de Clínicas, Universidade Estadual de Campinas - Campinas (SP), Brazil.ORCID 0000-0001-7380-0314
Isabel de Siqueira FerrazPediatric Intensive Care Unit, Department of Pediatrics, Hospital de Clínicas, Universidade Estadual de Campinas - Campinas (SP), Brazil.ORCID 0000-0002-3818-0129
Marcelo Barciela BrandãoPediatric Intensive Care Unit, Department of Pediatrics, Hospital de Clínicas, Universidade Estadual de Campinas - Campinas (SP), Brazil.ORCID 0000-0001-9155-2182
Tiago Henrique de SouzaPediatric Intensive Care Unit, Department of Pediatrics, Hospital de Clínicas, Universidade Estadual de Campinas - Campinas (SP), Brazil.ORCID 0000-0001-6944-0221

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiac output is an essential determinant of oxygen delivery, although unreliably measured on clinical examination and routine monitoring. Unfortunately, cardiac output monitoring is rarely performed in pediatric critical care medicine, with a limited availability of accurate methods for children. Herein, we report two pediatric cases in which noninvasive pulse-wave transit time-based cardiac output monitoring (esCCO, Nihon Kohden, Tokyo, Japan) was used. The esCCO system calculates cardiac output continuously by using the negative correlation between stroke volume and pulse wave transit time and requires only electrocardiogram monitoring, noninvasive blood pressure, and pulse oximetry signals. Before starting its use, esCCO should be calibrated, which can be done using patient information (gender, age, height, and body weight) or entering cardiac output values obtained by other methods. In both cases, when calibrations were performed using patient information, the agreement between esCCO and echocardiographic measurements was poor. However, after calibration with transthoracic echocardiography, the cardiac output values obtained by both methods remained similar after 2 hours and 18 hours. The results indicate that the esCCO system is suitable for use in children; however, further studies are needed to optimize its algorithm and determine its accuracy, precision, and trend in children.

Indexed as

AlgorithmsCritical IllnessBody WeightCardiac OutputChildHumansStroke VolumeCardiac outputChildCritically illnessHemodynamic monitoringPulse wave analysisShock

Identifiers

PMID37712737
PMCPMC10275300

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.