Stability of Three-Dimensional Printed Custom-Made Metaphyseal Cone for Tibial Bone Defects Reconstruction: A Finite Element Analysis and Biomechanical Study.

Xinguang Wang, Xinyu Li, Cheng Wang, Xiao Geng, Bo Chen, Ziyang Dong, Yang Li, Minwei Zhao, Zijian Li, Feng Li and 2 more

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 2 institutions in 1 country.

Xinguang WangDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.ORCID https://orcid.org/0000-0002-9163-1945
Xinyu LiBeijing 3D Printing Orthopedic Application Engineering Technology Research Center, Beijing, China.
Cheng WangDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.
Xiao GengDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.
Bo ChenBeijing 3D Printing Orthopedic Application Engineering Technology Research Center, Beijing, China.
Ziyang DongDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.ORCID https://orcid.org/0000-0002-2265-481X
Yang LiDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.
Minwei ZhaoDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.ORCID https://orcid.org/0000-0003-0319-873X
Zijian LiDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.
Feng LiDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.
Caimei WangBeijing 3D Printing Orthopedic Application Engineering Technology Research Center, Beijing, China.
Hua TianDepartment of Orthopaedics, Peking University Third Hospital, Beijing, China.ORCID https://orcid.org/0000-0001-7139-3372
Peking University · CNChina Academy of Printing Technology · CN

Funding

Beijing Natural Science Foundation Program 23G12187
6 · The paper itself

Abstract

objectivesThe reconstruction of bone defects in tibial revision knee arthroplasty is challenging. In this study, we evaluated the primary stability of a novel three-dimensional (3D)-printed custom-made metaphyseal cone for Anderson Orthopedic Research Institute (AORI) IIb or III bone defect reconstruction in tibial revision knee arthroplasty using the combination of finite-element analysis and biomechanical experiments.

methodsIn the finite-element analysis, AORI II b and III medial tibial bone defects were designed at varying depths. A novel 3D-printed custom-made metaphyseal cone was designed and used to reconstruct the bone defect with or without a stem in simulated revision total knee arthroplasty (RTKA). A no-stem group and a stem group were established (based on whether a stem was used or not). Von Mises stress and micromotion were calculated with varying depths of bone defects, ranging from 5 mm to 35 mm, and then micromotions at the bone-implant interface were calculated and compared with the critical value of 150 μm. In the biomechanical experiment, the no-stem group was used, and the same bone defects were made in four synthetic tibias using patient-specific instruments. Micromotions at the bone-implant interface were investigated using a non-contact optical digital image correlation system and compared with the critical value of 150 μm.

resultsWhen the bone defect was <30 mm, micromotions at the bone-implant interface in the finite-element analysis were all below 150 μm both in the stem groups and no-stem groups, whereas those in the biomechanical experiment were also below 150 μm in the no-stem group.

conclusionsThe 3D-printed custom-made metaphyseal cone in RTKA has excellent primary stability and does not require stems in reconstructing tibial AORI type IIb or III bone defects with a depth of <30 mm.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisBone and BonesFinite Element AnalysisHumansKnee JointProsthesis DesignReoperationTibia3D PrintedBone DefectMetaphyseal ConeRevision Total Knee Arthroplasty

Identifiers

PMID37712186
PMCPMC10622292
OpenAlexW4386757160

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.