Evidence map›Paper›PMID 37712074›Full record

ArticleArthroplasty today2023

Free Hip Arthroplasty Templating Software - Does it Work?

Alex C Jouflas, Syed Furqan Gilani, Arun C Nadar, John Whitaker, Jon B Carlson

Abstract read
In one paragraph

Article in Arthroplasty today, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Alex C JouflasDepartment of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA.
Syed Furqan GilaniDepartment of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA.
Arun C NadarDepartment of Orthopaedic Surgery, University of Louisville School of Medicine, Louisville, KY, USA.
John WhitakerDepartment of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA.
Jon B CarlsonDepartment of Orthopaedic Surgery, University of Louisville, Louisville, KY, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Preoperative planning is important for successful total hip arthroplasty (THA) and has been historically performed using acetate templates. Digital software templating has been adopted for evaluating implant size, position, and alignment. Commercial software can be expensive, but free programs exist. Detroit Bone Setter (detroitbonesetter.com, Detroit, MI) is a freely available templating program, but hasn't been validated. Our study reports this program's accuracy for templating THA. Methods: Sixty-five patients undergoing THA between 2017 and 2022 at 2 hospitals were included. All cases were templated by the senior author or orthopaedic trauma fellow prospectively or retrospectively in a blinded fashion. Direct anterior or posterior approaches were used based on attending surgeon's preference. A student's t-test was used to compare means of templated vs actual implant sizes of femoral and acetabular components. Results: There was no significant difference between implanted (mean [M] = 6.4, standard deviation [SD] = 2.0) and templated femoral component sizes (M = 5.7, SD = 2.1). There was a significant difference between implanted (M = 57.0, SD = 3.9) and templated acetabular component sizes (M = 53.4, SD = 3.0). Bland-Altman testing demonstrated femoral components with positive measurement bias of 0.62, indicating slight overestimation of implant size. Acetabular component size was overestimated with positive measurement bias of 3.6 mm. Conclusions: Detroit Bone Setter is advantageous as it is freely available and supports most major company implants. It accurately templated femoral component size but consistently overestimated acetabular component size by 3.6 mm. Further studies are needed prior to recommending its routine use for templating THA when other validated methods exist. It could be used with caution when no other methods are available.

Indexed as

ArthroplastyDigitalHemiarthroplastyPlanningTemplating

Identifiers

PMID37712074
PMCPMC10498402

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.