Evidence map›Paper›PMID 37710415›Full record

ArticleESC heart failure2023

The kinocardiograph for assessment of fluid status in patients with acute decompensated heart failure.

Cyrille Herkert, Ignace De Lathauwer, Mayke van Leunen, Rudolph Ferdinand Spee, Paniz Balali, Pierre-Francois Migeotte, Amin Hossein, Yuan Lu, Hareld Marijn Clemens Kemps

Open access · goldAbstract read
In one paragraph

Article in ESC heart failure, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.6field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 2 countries.

Cyrille HerkertDepartment of Cardiology, Máxima Medical Centre, Eindhoven, The Netherlands.ORCID 0000-0002-1191-8322
Ignace De LathauwerDepartment of Cardiology, Máxima Medical Centre, Eindhoven, The Netherlands.
Mayke van LeunenDepartment of Cardiology, Máxima Medical Centre, Eindhoven, The Netherlands.
Rudolph Ferdinand SpeeDepartment of Cardiology, Máxima Medical Centre, Eindhoven, The Netherlands.
Paniz BalaliLPHYS, Université Libre de Bruxelles, Brussels, Belgium.
Pierre-Francois MigeotteLPHYS, Université Libre de Bruxelles, Brussels, Belgium.
Amin HosseinLPHYS, Université Libre de Bruxelles, Brussels, Belgium.
Yuan LuDepartment of Industrial Design, Eindhoven University of Technology, Eindhoven, The Netherlands.
Hareld Marijn Clemens KempsDepartment of Cardiology, Máxima Medical Centre, Eindhoven, The Netherlands.
Radboud University Nijmegen · NLUniversité Libre de Bruxelles · BEEindhoven University of Technology · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsTo improve telemonitoring strategies in heart failure patients, there is a need for novel non-obtrusive sensors that monitor parameters closely related to intracardiac filling pressures. This proof-of-concept study aims to evaluate the responsiveness of cardiac kinetic energy (KE) measured with the Kinocardiograph (KCG), consisting of a seismocardiographic (SCG) sensor and a ballistocardiographic (BCG) sensor, during treatment of patients with acute decompensated heart failure. METHODS AND

resultsEleven patients with acute decompensated heart failure who were hospitalized for treatment with intravenous diuretics received daily KCG measurements. The KCG measurements were compared with the diameter of the inferior vena cava (IVC) and body weight. Follow-up stopped at discharge, that is, in the recompensated state. Median (interquartile range) weight and IVC diameter decreased significantly after diuretic treatment [weight 74.5 (67.6-98.7) to 73.3 (66.7-95.6) kg, P = 0.003; IVC diameter 2.47 (2.33-2.99) to 1.78 (1.65-2.47) cm, P = 0.03]. In contrast with BCG measurements, significant changes in median KE measured with SCG were observed during the passive filling phase of the diastole [SGG: 0.48 (0.39-0.60) to 0.69 (0.56-0.84), P = 0.026; BCG: 0.68 (0.46-0.73) to 0.68 (0.59-0.82), P = 0.062], the active filling phase of the diastole [SCG: 0.38 (0.30-0.61) to 0.31 (0.09-0.47), P = 0.016; BCG: 0.29 (0.17-0.39) to 0.26 (0.20-0.34), P = 0.248], and the ratio between the passive and active filling phases [SCG: 2.76 (1.68-5.30) to 5.02 (3.13-10.17), P = 0.006; BCG: 5.87 (3.57-7.55) to 5.27 (3.95-9.43), P = 0.790]. The correlations between changes in KE during the passive and active filling phases, using SCG, and changes in weight or IVC were non-significant. Systolic KE did not show significant changes.

conclusionKE measured with the KCG using SCG is highly responsive to changes in fluid status. Future research is needed to confirm its accuracy in a larger study population and specifically its application for detection of clinical deterioration in the home-environment.

Indexed as

Heart FailureDiastoleDiureticsHeartHumansSystoleDiureticsBallistocardiographyHeart failureKinetic energySeismocardiographyTelemonitoring

Identifiers

PMID37710415
PMCPMC10682902
OpenAlexW4386758292

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.