ArticlePloS one2023
Endotracheal tube, by the venturi effect, reduces the efficacy of increasing inlet pressure in improving pendelluft.
Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Three-dimensional upper airway phenotyping and OSA severity: a CT-based study.European radiology · 2026Article
- Inspiratory effort increases blood volume in the thoracic cavity and decreases end-expiratory lung impedance: a preliminary prospective study.European journal of applied physiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In mechanically ventilated severe acute respiratory distress syndrome patients, spontaneous inspiratory effort generates more negative pressure in the dorsal lung than in the ventral lung. The airflow caused by this pressure difference is called pendelluft, which is a possible mechanisms of patient self-inflicted lung injury. This study aimed to use computer simulation to understand how the endotracheal tube and insufficient ventilatory support contribute to pendelluft. We established two models. In the invasive model, an endotracheal tube was connected to the tracheobronchial tree with 34 outlets grouped into six locations: the right and left upper, lower, and middle lobes. In the non-invasive model, the upper airway, including the glottis, was connected to the tracheobronchial tree. To recreate the inspiratory effort of acute respiratory distress syndrome patients, the lower lobe pressure was set at -13 cmH2O, while the upper and middle lobe pressure was set at -6.4 cmH2O. The inlet pressure was set from 10 to 30 cmH2O to recreate ventilatory support. Using the finite volume method, the total flow rates through each model and toward each lobe were calculated. The invasive model had half the total flow rate of the non-invasive model (1.92 L/s versus 3.73 L/s under 10 cmH2O, respectively). More pendelluft (gas flow into the model from the outlets) was observed in the invasive model than in the non-invasive model. The inlet pressure increase from 10 to 30 cmH2O decreased pendelluft by 11% and 29% in the invasive and non-invasive models, respectively. In the invasive model, a faster jet flowed from the tip of the endotracheal tube toward the lower lobes, consequently entraining gas from the upper and middle lobes. Increasing ventilatory support intensifies the jet from the endotracheal tube, causing a venturi effect at the bifurcation in the tracheobronchial tree. Clinically acceptable ventilatory support cannot completely prevent pendelluft.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.