ArticleIrish journal of medical science2024

Water immersion ultrasound can improve the repeatability of ultrasonic measurement of dorsalis pedis artery diameter and hemodynamic parameters.

Zhijun Zhang, Yuxi Xu, Zhaoyang Hao, Hui Wang

Abstract read
PubMed Publisher
In one paragraph

Article in Irish journal of medical science, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Zhijun ZhangDepartment of Ultrasound, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China.ORCID http://orcid.org/0000-0002-4800-0291
Yuxi XuDepartment of Ultrasound, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China.
Zhaoyang HaoDepartment of Ultrasound, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China.
Hui WangDepartment of Ultrasound, University-Town Hospital of Chongqing Medical University, Chongqing, 401331, China. 800246@hospital.cqmu.edu.cn.
Chongqing Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveIn comparing the repeatability of the internal diameter and hemodynamic parameters of the dorsalis pedis artery measured by immersion ultrasound and contact ultrasound, the factors affecting the accuracy and repeatability of measurement were analyzed. This study aimed to provide a better method for ultrasound evaluation of the dorsalis pedis artery before flap transplantation.

methodsTwo senior sonographers measured the diameter of the dorsalis pedis artery (D) of 56 healthy volunteers, measuring at the same location and at different time points using water immersion and contact ultrasound. Color Doppler ultrasound was used to measure the hemodynamics of the dorsalis pedis artery, including peak systolic velocity (PSV), end diastolic velocity (EDV), and resistance index (RI). The interclass correlation coefficient (ICC) was used to evaluate the intraobserver and interobserver repeatability for each group's measurements.

resultsThe intraobserver and interobserver reproducibility of D, PSV, EDV, and RI measurements by water immersion ultrasound was very good. The intraobserver and interobserver reproducibility of the contact ultrasound measurements of D, PSV, EDV, and RI was good.

conclusionThe repeatability of water immersion ultrasound is better than that of contact ultrasound in the measurement of the dorsalis pedis artery. Water immersion ultrasound can improve the near-field resolution of superficial tissues and increase the display of the lengths of blood vessels in images, thereby suggesting its superiority in ultrasound examination of dorsalis pedis arteries.

Indexed as

ImmersionUltrasonicsArteriesHemodynamicsHumansReproducibility of ResultsDorsalis pedis arteryFlap transplantationUltrasoundWater immersion

Identifiers

PMID37707689
OpenAlexW4386725954

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.