Evidence map›Paper›PMID 37705757›Full record

ArticleAmerican journal of ophthalmology case reports2023

Use of PROSE for long-term ocular surface support in patients with a permanent keratoprosthesis.

Bita Asghari, Karen G Carrasquillo, Alan Kwok, Kimberly C Sippel

Abstract readCase Reports
In one paragraph

Article in American journal of ophthalmology case reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Two cases of therapeutic scleral lenses for KID syndrome.American journal of ophthalmology case reports · 2025
    Article
  3. Scleral lenses and PROSE: indications, complications, and future challenges.Medical hypothesis, discovery & innovation ophthalmology journal · 2025
    Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Bita AsghariBostonSight, 464 Hillside Ave., Unit 205, Needham, MA, 02494, USA.
Karen G CarrasquilloBostonSight, 464 Hillside Ave., Unit 205, Needham, MA, 02494, USA.
Alan KwokBostonSight, 464 Hillside Ave., Unit 205, Needham, MA, 02494, USA.
Kimberly C SippelWeill Cornell Medicine, 1305 York Ave., 12th Floor, New York, NY, 10021, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: To describe the long-term outcome of the use of a specialized scleral lens known as a prosthetic replacement of the ocular surface ecosystem (PROSE) device to support the ocular surface in patients with a Boston Keratoprosthesis (KPro) Type I. All patients in this series were unable to pursue continuous wear of a bandage soft contact lens (BSCL) - a critical aspect of post KPro implantation management intended to protect the corneal carrier tissue from desiccation and stromal melting. Observations: Four eyes of four patients with a Boston KPro Type I were included. All four had failed BSCL wear and were instead treated with PROSE device wear. All four patients had underlying diagnoses associated with a diseased ocular surface (Stevens-Johnson Syndrome [one patient], prior failed penetrating keratoplasty associated with herpes zoster-related neurotrophic keratopathy [one patient], and prior failed penetrating keratoplasty associated with severe dry eye disease [two patients]). Causes of failure of BSCL wear included poor retention, discomfort, and poor vision. PROSE device wear was initiated on average seven and a half (range four to 14) months post-KPro implantation. The wear schedule varied and ranged from waking-hour wear only to 24-h wear. The average duration of device wear was 59.3 (range 28-103) months. Two patients exhibited persistent corneal epithelial defect formation with waking-hour wear, which resolved within 10 days with 24-h device wear. All patients exhibited improvement in vision with PROSE compared to baseline, averaging six and a half (range six to eight) lines of improvement in Snellen acuity, and all patients reported increased comfort. There was no incidence of microbial keratitis, KPro device instability, or other complication throughout the duration of device wear. Conclusions and Importance: This report offers a novel alternate approach to long-term support of the ocular surface in patients with a Boston KPro who fail standard continuous BSCL wear.

Indexed as

KeratoprosthesisOcular surface diseaseOvernight scleral lens wearPersistent epithelial defectPROSE deviceScleral lens