Evidence map›Paper›PMID 37705412›Full record

ArticleMagnetic resonance in medicine2024

Improved

Simon Schmidt, M Arcan Ertürk, Xiaoxuan He, Tobey Haluptzok, Yiğitcan Eryaman, Gregory J Metzger

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. 10.5 T In Vivo Head Imaging With Universal RF Shimming.Magnetic resonance in medicine · 2026
    Article
  4. First In VivoMagnetic resonance in medicine · 2026
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. A Quantitative Comparison ofSensors (Basel, Switzerland) · 2024
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Simon SchmidtCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.ORCID 0000-0003-1835-4002
M Arcan ErtürkCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.
Xiaoxuan HeCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.ORCID 0000-0003-0885-912X
Tobey HaluptzokCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.
Yiğitcan EryamanCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.
Gregory J MetzgerCenter for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.ORCID 0000-0002-3187-6529

Funding

TRD4 - Ultrahigh Field Engineering and SafetyP41EB027061 · NIBIB · UNIVERSITY OF MINNESOTA · PI Gregory John Metzger, KAMIL UGURBIL · 2019 to 2026
$11.7M
Computer Aided Diagnostic System for Prostate Cancer Detection Using Quantitative Multiparametric MRIR01CA241159 · NCI · UNIVERSITY OF MINNESOTA · PI METZGER, GREGORY JOHN · 2021 to 2025
$3.0M
Development of Enabling Technologies for Clinical Ultrahigh Field Body MRIR01EB029985 · NIBIB · UNIVERSITY OF MINNESOTA · PI METZGER, GREGORY JOHN · 2021 to 2024
$2.4M
Safe Magnetic Resonance Imaging of Patients with Deep Brain Stimulation SystemsR01NS115180 · NINDS · UNIVERSITY OF MINNESOTA · PI ERYAMAN, YIGITCAN · 2020 to 2024
$1.9M
NCI NIH HHS R01 CA241159NIBIB NIH HHS P41 EB027061NIBIB NIH HHS R01 EB029985NINDS NIH HHS R01 NS115180
6 · The paper itself

Abstract

purposeTo increase the RF coil performance and RF management for body imaging at 10.5 T by validating and evaluating a high-density 16-channel transceiver array, implementing virtual observation points (VOPs), and demonstrating specific absorption rate (SAR) constrained imaging in vivo.

methodsThe inaccuracy of the electromagnetic model of the array was quantified based on B

resultsThe model inaccuracy of 29% and the inter-subject variability of 85% resulted in a total safety factor of 1.91 for pelvis studies. For renal and cardiac imaging, inter-subject variabilities of 121% and 141% lead to total safety factors of 2.25 and 2.45, respectively. The shorter wavelength at 10.5 T supported the increased element density of the 16-channel array which in turn outperformed the 10-channel version for all investigated metrics. Peak 10 g local SAR reduction of more than 25% without a loss of image quality was achieved in vivo, allowing a theoretical improvement in measurement efficiency of up to 66%.

conclusionsBy validating and characterizing a 16-channel dipole transceiver array, this work demonstrates, for the first time, a VOP-enabled RF coil for human torso imaging enabling increased pTx performance at 10.5 T.

Indexed as

Magnetic Resonance ImagingProstateComputer SimulationEquipment DesignHumansMalePhantoms, ImagingRadio Waves10.5 Tbody imagingMRIparallel transmitultra-high field imagingvalidation

Identifiers

PMID37705412
PMCPMC10850915

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.