ArticleClinical ophthalmology (Auckland, N.Z.)2023
Comparing the Accuracy of the Kane, Barrett Universal II, Hill-Radial Basis Function, Emmetropia Verifying Optical, and Ladas Super Formula Intraocular Lens Power Calculation Formulas.
Article in Clinical ophthalmology (Auckland, N.Z.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 15 citations in OpenAlex.
- Accuracy of the European Society of Cataract and Refractive Surgeons Online Calculator for Enhanced Monofocal Intraocular Lens Power Calculation.Korean journal of ophthalmology : KJO · 2026Article
- Evaluation of a Simple and Accurate Method for Intraocular Lens Constant Optimization Using Linear Interpolation.Journal of clinical medicine · 2025Article
- Does gender affect intraocular lens power calculations? A comparative analysis of formula accuracy.Journal of medicine and life · 2025Observational
- Comparative Analysis of Intraocular Lens Power Calculation Formulas (Kane, Barrett Universal II, Hill-Radial Basis Function, and Ladas Super Formula): Which One Is More Accurate?Journal of clinical medicine · 2025Article
- Accuracy assessment of artificial intelligence IOL calculation formulae: utilizing the heteroscedastic statistics and the Eyetemis Analysis Tool.Eye (London, England) · 2024Article
- Short-term variability in ocular biometry and the impact of preoperative dry eye.Scientific reports · 2024Article
- Associations of ocular anterior segment structures with sex and age: the Yamagata study (Funagata).Japanese journal of ophthalmology · 2024Article
- Background of Minimally Invasive Glaucoma Surgery (MIGS)-Adapted Patients for Cataract Surgery in Glaucoma.Journal of clinical medicine · 2024Article
- A Multi Comparison of 8 Different Intraocular Lens Biometry Formulae, Including a Machine Learning Thin Lens Formula (MM) and an Inbuilt Anterior Segment Optical Coherence Tomography Ray Tracing Formula.Vision (Basel, Switzerland) · 2024Article
- Accuracy Validation of the New Barrett True Axial Length Formula and the Optimized Lens Factor Using Sum-of-Segment Biometry.Journal of clinical medicine · 2024Article
- Predictability of Existing IOL Formulas After Cataract Surgery in Patients with a Previous History of Radial Keratotomy: A Retrospective Cohort Study and Literature Review.Ophthalmology and therapy · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Purpose: To assess the accuracy of five new-generation intraocular lens (IOL) power formulas: Barrett Universal II (BUII), Emmetropia Verifying Optical (EVO) Formula, Hill-Radial Basis Function (Hill-RBF), Kane Formula, and Ladas Super Formula (LSF). Patients and Methods: This is a retrospective single-surgeon study from a refractive clinic and clinical research center in Draper, UT, USA. The primary outcome measures were mean absolute error (MAE) and median absolute error (MedAE). Secondary outcome measures were the standard deviation (SD) of each formula's refractive prediction errors (RPE) and the percentage of eyes within ±0.50D. Refractive predictions were compared to the postoperative spherical equivalent to determine the RPE for each formula. RPEs were optimized, and MAE, MedAE, SD of the AME, and percent of eyes achieving RPEs within the specified ranges of ±0.125 D, ±0.25 D, ±0.50 D, ±0.75 D, ±1.0 D were calculated. Subgroup analysis between different axial lengths was attempted but yielded insufficient statistical power to draw meaningful conclusions. Results: A total of 103 eyes of 103 patients were included in our study after applying inclusion and exclusion criteria to 606 eyes from 2019 to 2021. Formulas ranked in ascending order by MAE were Kane, EVO, BUII, Hill-RBF, and LSF. The ascending rankings of MedAE were Kane, BUII, Hill-RBF, EVO, Ladas. Kane had a significantly lower MAE than Hill-RBF (p<0.001). EVO had the lowest SD of AMEs and the highest percentage of eyes within ±0.50 D. According to heteroscedastic testing, EVO also had a statistically significant lower SD than Hill-RBF. Conclusion: Kane was the most accurate formula in terms of MAE and MedAE. EVO and BUII achieved marginally higher MAEs than Kane, suggesting these three formulas are comparable in performance. With the exception EVO and Hill-RBF, the heteroscedastic test yielded no significant differences in SD between the formulas. Although there were multiple statistically significant differences between the formulas in terms of MAE, MedAE, and SD, these differences may not be appreciable clinically. Lastly, there were no statistically significant differences in the percent of eyes with RPEs within ±0.50 D, suggesting similar clinical performance between formulas.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.