ReviewNature protocols2023
Modified Neuropixels probes for recording human neurophysiology in the operating room.
Review in Nature protocols, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06617208 (Prognostic IntraOperative Biomarkers ideNtification in Tumor rElatEd suRgery), which is not on this map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Prognostic IntraOperative Biomarkers ideNtification in Tumor rElatEd suRgery (PIONEER Study)
Who cites it
23 citing papers in PubMed.
- Shared neural geometries for bilingual semantic representations in human hippocampal neurons.Cell · 2026Article
- Review
- Large-scale electrophysiology at single-spike resolution.Nature reviews. Neuroscience · 2026Review
- Article
- A clinically integrated, frameless human Neuropixels workflow.medRxiv : the preprint server for health sciences · 2026Article
- Large-scale single-neuron recording in the human cortex using an ultra-flexible electrode array.Nature communications · 2026Article
- Advancing neuroengineering with Neuromorphic Twins.Nature communications · 2026Review
- Article
- Microscale maps of bursting dynamics across human hippocampal slices from patients with epilepsy.Journal of neurophysiology · 2026Article
- A modular and flexible pipeline for intraoperative electrode reconstruction and localization in patients with brain lesions.Frontiers in neural circuits · 2026Article
- Ripple contributions to human memory: making the spiking content count.Nature reviews. Neuroscience · 2025Review
- From reactive to proactive: Continuous protein monitoring for preventive health care.Science (New York, N.Y.) · 2025Review
- Advances in large-scale electrophysiology with high-density microelectrode arrays.Lab on a chip · 2025Review
- Pathological microcircuits and epileptiform events in patient hippocampal slices.bioRxiv : the preprint server for biology · 2025Article
- Article
- Recent Progress of Soft and Bioactive Materials in Flexible Bioelectronics.Cyborg and bionic systems (Washington, D.C.) · 2025Review
- The Eastern Association of Electroencephalographers: A Canadian/USA success story.Clinical neurophysiology practice · 2025Review
- Electrophysiology of gliomas: current science, implications, and opportunities.Frontiers in oncology · 2025Review
- Emerging Medical Technologies and Their Use in Bionic Repair and Human Augmentation.Bioengineering (Basel, Switzerland) · 2024Review
- Computer vision-guided open-source active commutator for neural imaging in freely behaving animals.Neurophotonics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
23 authors.
Funding
Abstract
Neuropixels are silicon-based electrophysiology-recording probes with high channel count and recording-site density. These probes offer a turnkey platform for measuring neural activity with single-cell resolution and at a scale that is beyond the capabilities of current clinically approved devices. Our team demonstrated the first-in-human use of these probes during resection surgery for epilepsy or tumors and deep brain stimulation electrode placement in patients with Parkinson's disease. Here, we provide a better understanding of the capabilities and challenges of using Neuropixels as a research tool to study human neurophysiology, with the hope that this information may inform future efforts toward regulatory approval of Neuropixels probes as research devices. In perioperative procedures, the major concerns are the initial sterility of the device, maintaining a sterile field during surgery, having multiple referencing and grounding schemes available to de-noise recordings (if necessary), protecting the silicon probe from accidental contact before insertion and obtaining high-quality action potential and local field potential recordings. The research team ensures that the device is fully operational while coordinating with the surgical team to remove sources of electrical noise that could otherwise substantially affect the signals recorded by the sensitive hardware. Prior preparation using the equipment and training in human clinical research and working in operating rooms maximize effective communication within and between the teams, ensuring high recording quality and minimizing the time added to the surgery. The perioperative procedure requires ~4 h, and the entire protocol requires multiple weeks.
Indexed as
Identifiers
37697108What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.