Evidence map›Paper›PMID 37695790›Full record

ArticlePloS one2023

Regulation of multi-area power system load frequency in presence of V2G scheme.

Mahmoud M Hussein, Tarek Hassan Mohamed, Mohamed Metwally Mahmoud, Mansour Aljohania, Mohamed I Mosaad, Ammar M Hassan

Abstract read
In one paragraph

Article in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mahmoud M HusseinDepartment of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, Egypt.
Tarek Hassan MohamedDepartment of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, Egypt.
Mohamed Metwally MahmoudDepartment of Electrical Engineering, Faculty of Energy Engineering, Aswan University, Aswan, Egypt.ORCID 0000-0002-2460-1850
Mansour AljohaniaElectrical & Electronics Engineering Technology Department, Yanbu Industrial College (YIC), Royal Commission Yanbu Colleges & Institutes, Yanbu, Saudi Arabia.
Mohamed I MosaadElectrical & Electronics Engineering Technology Department, Yanbu Industrial College (YIC), Royal Commission Yanbu Colleges & Institutes, Yanbu, Saudi Arabia.
Ammar M HassanArab Academy for Science, Technology and Maritime Transport, South Valley Branch, Aswan, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The integration of renewable sources (RSs) and the widespread deployment of electric vehicles (EVs) has transitioned from a luxury to a necessity in modern power systems. This results from the sharp increase in electric power demand and public awareness of switching to green energy. However, in addition to load fluctuations and changes in system parameters, these RSs and EVs negatively impact the load frequency (LF). This work presents a LF control for a modern multi-area power system incorporating photovoltaic (PV) and EV chargers. The proposed controller primarily utilizes EV chargers within modern power systems. This approach offers the advantage of using the already present components instead of introducing new ones. The proposed controller comprises the ecological optimization approach (ECO) and the integral controller (I). Both of these components are designed for autonomous vehicle-to-grid (V2G) devices. The proposed control technique is applied to a three-area power system, where the V2G scheme is located in Area-1. Variations in the load, PV power generated, and system parameters are considered to evaluate the effectiveness of the proposed (I+ECO+V2G) controller for controlling the LF. To assess the performance of the proposed I+ECO+V2G system, a comparative analysis is conducted to compare its performance with both the I+ECO system and the standard I-controller. The simulation findings demonstrate that implementing the I+ECO and the proposed I+ECO+V2G strategies results in enhanced system stability and decreased LF fluctuations compared to the conventional I-control approach. Furthermore, while comparing the I+ECO control technique to the suggested control strategy I+ECO+V2G, it was seen that the latter reaches steady state values more quickly. The results validate the robustness and effectiveness of the proposed controller in mitigating the impacts of load disturbances, uncertainties, and nonlinearities within the system. These simulations were performed using MATLAB/SIMULINK. To validate the outcomes of the simulation results, an experimental setup consisting of a real-time dSPACE DS1103 connected to another PC via QUARC pid_e data acquisition card was used. The experimental findings have substantiated the accuracy of the simulation findings about the superiority of the I+ECO+V2G methodology compared to both the I+ECO and I-control methodologies concerning system performance and LF control.

Identifiers

PMID37695790
PMCPMC10495024

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.