Evidence map›Paper›PMID 37691993›Full record

ArticleCurrent urology2023

Laser speckle contrast imaging compared with indocyanine green in renal perfusion of a porcine model.

Jonathan Noël, Anya Mascarenhas, Chibueze A Nwaiwu, Yao Liu, Marcio Moschovas, Vasiliy E Buharin, John Oberlin, Saloni Mehrotra, Alyson F Dechert, Peter C W Kim and 1 more

Open access · diamondAbstract read
In one paragraph

Article in Current urology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 1 country.

Jonathan NoëlDepartment of Urology, AdventHealth Global Robotics Institute, Celebration, FL, USA.
Anya MascarenhasHarvard University, Cambridge, MA, USA.
Chibueze A NwaiwuDepartment of Surgery, Warren Alpert Medical School of Brown University, Rhode Island Hospital, Providence, RI, USA.
Yao LiuDepartment of Surgery, Warren Alpert Medical School of Brown University, Rhode Island Hospital, Providence, RI, USA.
Marcio MoschovasDepartment of Urology, AdventHealth Global Robotics Institute, Celebration, FL, USA.
Vasiliy E BuharinDepartment of Research, Activ Surgical Inc., Boston, MA, USA.
John OberlinDepartment of Research, Activ Surgical Inc., Boston, MA, USA.
Saloni MehrotraDepartment of Research, Activ Surgical Inc., Boston, MA, USA.
Alyson F DechertDepartment of Research, Activ Surgical Inc., Boston, MA, USA.
Peter C W KimDepartment of Surgery, Warren Alpert Medical School of Brown University, Rhode Island Hospital, Providence, RI, USA.
Vipul PatelDepartment of Urology, AdventHealth Global Robotics Institute, Celebration, FL, USA.
AdventHealth Celebration · USBrown University · USHarvard University Press · USRhode Island Hospital · USUniversity at Buffalo, State University of New York · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: When viewed under near-infrared light, indocyanine green (ICG) signal for kidney perfusion can be utilized in partial nephrectomy. Laser speckle contrast imaging (LSCI) uses coherent light to detect perfusion during real-time laparoscopic surgery. Materials and methods: Laser speckle contrast imaging or ActivSight, an imaging sensor adapter, was used during laparoscopy of an anesthetized porcine kidney model. ActivSight's "perfusion mode" and "quantification mode" displayed the blood flow as a heatmap and numerical signal intensity, respectively. Results: After the upper segmental renal artery was clamped, ICG was seen in the lower pole, and LSCI showed low unit (dark color) quantification and perfusion in the upper pole. Indocyanine green was retained in the lower pole after the upper segmental artery was unclamped, and LSCI perfusion was demonstrated in the entire kidney. Conclusions: Laser speckle contrast imaging is a dye-free, repeatable, real-time adjunct for renal parenchymal perfusion assessment applicable to minimally invasive renal surgery to complement the technology of ICG near-infrared fluorescence and advance digital surgery.

Indexed as

Augmented realityIndocyanine greenLaser speckle contrast imagingPerfusionSelective arterial clamping

Identifiers

PMID37691993
PMCPMC10489255
OpenAlexW4297325212

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.