Design of a lightweight universal talus implant using topology optimization.

Ahmed H Hafez, Marwan El-Rich, Tao Liu, Nadr Jomha, Andreas Schiffer

Open access · goldAbstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.5field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Ahmed H HafezDepartment of Mechanical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates.
Marwan El-RichDepartment of Mechanical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates.
Tao LiuHuman Performance Lab, Faculty of Kinesiology, University of Calgary, Calgary, AB, Canada.
Nadr JomhaFaculty of Medicine and Dentistry, University of Alberta, Edmonton, AB, Canada.
Andreas SchifferDepartment of Mechanical Engineering, Khalifa University, Abu Dhabi, United Arab Emirates.
Khalifa University of Science and Technology · AEUniversity of Alberta · CAUniversity of Calgary · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Total talus replacement is a promising alternative treatment for talus fractures complicated by avascular necrosis and collapse. This surgical option replaces the human talus bone with a customized talus implant and can maintain ankle joint functionality compared to traditional treatment (e.g., ankle fusion). However, the customized implant is costly and time-consuming due to its customized nature. To circumvent these drawbacks, universal talus implants were proposed. While they showed clinically satisfactory results, existing talus implants are heavier than biological talus bones as they are solid inside. This can lead to unequal weight between the implant and biological talus bone, and therefore leading to other complications. The reduction of the implants' weight without compromising its performance and congruency with surrounding bones is a potential solution. Therefore, this study aims to design a lightweight universal talus implant using topology optimization. This is done through establishing the loading and boundary conditions for three common foot postures: neutral, dorsi- and plantar-flexion. The optimized implant performance in terms of mass, contact characteristics with surrounding joint cartilage and stress distributions is studied using a 3D Finite Element (FE) model of the ankle joint. The mass of the optimized implant is reduced by approximately 66.6% and its maximum stresses do not exceed 70 MPa, resulting in a safety factor of 15.7. Moreover, the optimized and solid implants show similar contact characteristics. Both implants produced peak contact pressures that were approximately 19.0%-196% higher than those produced by the biological talus. While further mechanical testing under

Indexed as

bioinspired designcartilagecontact pressurefinite element analysistalus implant designtopology optimizationtotal talus replacement

Identifiers

PMID37691900
PMCPMC10484404
OpenAlexW4386126023

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.