ArticleAudiology & neuro-otology2024
The Impact of Patient Factors on Objective Cochlear Implant Verification Using Acoustic Cortical Auditory-Evoked Potentials.
Article in Audiology & neuro-otology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- Using cortical auditory-evoked potential responses to verify the objective benefit of aural rehabilitation in adult cochlear implant users.Frontiers in neuroscience · 2026Article
- The intersubject reliability of cortical auditory evoked potential (CAEP) in pediatric cochlear implant recipients: comparisons between acoustic and electrical stimulations.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Article
- Investigating the effect of cochlear implant usage metrics on cortical auditory-evoked potential responses in adult recipients post-implantation.Frontiers in neuroscience · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionHearing loss is a major global public health issue that negatively impacts quality of life, communication, cognition, social participation, and mental health. The cochlear implant (CI) is the most efficacious treatment for severe-to-profound sensorineural hearing loss. However, variability in outcomes remains high among CI users. Our previous research demonstrated that the existing subjective methodology of CI programming does not consistently produce optimal stimulation for speech perception, thereby limiting the potential for CI users to derive the maximum device benefit to achieve their peak potential. We demonstrated the benefit of utilising the objective method of measuring auditory-evoked cortical responses to speech stimuli as a reliable tool to guide and verify CI programming and, in turn, significantly improve speech perception performance. The present study was designed to investigate the impact of patient- and device-specific factors on the application of acoustically-evoked cortical auditory-evoked potential (aCAEP) measures as an objective clinical tool to verify CI mapping in adult CI users with bilateral deafness (BD).
methodsaCAEP responses were elicited using binaural peripheral auditory stimulation for four speech tokens (/m/, /g/, /t/, and /s/) and recorded by HEARLab™ software in adult BD CI users. Participants were classified into groups according to subjective or objective CI mapping procedures to elicit present aCAEP responses to all four speech tokens. The impact of patient- and device-specific factors on the presence of aCAEP responses and speech perception was investigated between participant groups.
resultsParticipants were categorised based on the presence or absence of the P1-N1-P2 aCAEP response to speech tokens. Out of the total cohort of adult CI users (n = 132), 63 participants demonstrated present responses pre-optimisation, 37 participants exhibited present responses post-optimisation, and the remaining 32 participants either showed an absent response for at least one speech token post-optimisation or did not accept the optimised CI map adjustments. Overall, no significant correlation was shown between patient and device-specific factors and the presence of aCAEP responses or speech perception scores.
conclusionThis study reinforces that aCAEP measures offer an objective, non-invasive approach to verify CI mapping, irrespective of patient or device factors. These findings further our understanding of the importance of personalised CI rehabilitation through CI mapping to minimise the degree of speech perception variation post-CI and allow all CI users to achieve maximum device benefit.
Indexed as