Evidence map›Paper›PMID 37689969›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2023

Enhanced Detection of Suspicious Breast Lesions: A Comparative Study of Full-Field Digital Mammography and Automated Breast Ultrasound in 117 Patients with Core Needle Biopsy.

Marta Pawlak, Wojciech Rudnicki, Łukasz Brandt, Małgorzata Dobrowolska, Anna Borkowska, Joanna Szpor, Elżbieta Łuczyńska

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Marta PawlakDepartment of Radiology, University Hospital in Cracow, Cracow, Poland.
Wojciech RudnickiDepartment of Electroradiology, Jagiellonian University Medical College, Cracow, Poland.ORCID 0000-0003-2168-5638
Łukasz BrandtDepartment of Electroradiology, Jagiellonian University Medical College, Cracow, Poland.
Małgorzata DobrowolskaDepartment of Electroradiology, Jagiellonian University Medical College, Cracow, Poland.
Anna BorkowskaDepartment of Electroradiology, Jagiellonian University Medical College, Cracow, Poland.ORCID 0000-0002-6209-8299
Joanna SzporDepartment of Pathomorphology, Jagiellonian University Medical College, Cracow, Poland.
Elżbieta ŁuczyńskaDepartment of Electroradiology, Jagiellonian University Medical College, Cracow, Poland.ORCID 0000-0003-4872-7172
Jagiellonian University · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND This retrospective study from a single center aimed to compare the performance of full-field digital mammography (FFDM) vs automated breast ultrasound (ABUS) in the identification and characterization of suspicious breast lesions in 117 patients who underwent core-needle biopsy (CNB) of the breast. MATERIAL AND METHODS The study involved a group of 301 women. Every patient underwent FFDM followed by ABUS, which were assessed in concordance with BI-RADS (Breast Imaging Reporting and Data System) classification. RESULTS No focal lesions were found in 168 patients. In 133 patients, 117 histopathologically verified focal lesions were found. Among them, 78% appeared to be malignant and 22% benign. ABUS detected 246 focal lesions, including 115 classified as BI-RADS 4 or 5 and submitted to verification, while FFDM revealed 122 lesions, including 75 submitted to verification. The analysis revealed that combined application of both methods caused sensitivity to increase to 100, and improved accuracy improvement. Margin assessments in these examinations are consistent (P<0.00), the lesion's margin type with both methods depends on its malignant or benign character (P<0.03), lesion margins distribution on ABUS depends on estrogen receptor presence (P=0.033), and there was significant correlation between malignant character of the lesion and retraction phenomenon sign (P=0.033). ABUS obtained higher compliance between the size of the lesion in histopathology compared to FFDM (P>0.05). CONCLUSIONS The results shows that ABUS is comparable to FFDM, and even outperforms it in a few of the analyzed categories, suggesting that the combination of these 2 methods may have an important role in breast cancer detection.

Indexed as

Breast NeoplasmsMammographyBiopsy, Large-Core NeedleBreastFemaleHumansRetrospective Studies

Identifiers

PMID37689969
PMCPMC10501319
OpenAlexW4386541201

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.