Evidence map›Paper›PMID 37689744›Full record

ArticleScientific reports2023

Consistency of spectral results in cardiac dual-source photon-counting CT.

Leening P Liu, Nadav Shapira, Pooyan Sahbaee, Grace J Gang, Friedrich D Knollman, Marcus Y Chen, Harold I Litt, Peter B Noël

Abstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Spectral quantification in different lumen diameters for cardiovascular applications.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2024
    Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Leening P LiuDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, USA. leening.liu@pennmedicine.upenn.edu.
Nadav ShapiraDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
Pooyan SahbaeeSiemens Healthineers, Malvern, PA, USA.
Grace J GangDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
Friedrich D KnollmanDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
Marcus Y ChenNational Heart, Lung, and Blood Institute, Bethesda, MD, USA.
Harold I LittDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, USA.
Peter B NoëlDepartment of Radiology, University of Pennsylvania, Philadelphia, PA, USA. pbnoel@upenn.edu.

Funding

Patient-specific, high-sensitivity spectral CT for assessment of pancreatic cancerR01EB030494 · NIBIB · UNIVERSITY OF PENNSYLVANIA · PI GANG, JIANAN GRACE, NOËL, PETER B · 2021 to 2024
$2.4M
NIBIB NIH HHS R01 EB030494
6 · The paper itself

Abstract

We evaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT). A cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned at five different heart rates (0, 60-100 bpm) with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were calculated for virtual monoenergetic images (VMI) at 50, 70, and 150 keV and iodine density maps at both diastole and systole. FWHM averaged differences of - 0.20, - 0.28, and - 0.15 mm relative to static FWHM at VMI 150 keV across acquisition parameters for high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, and retrospectively ECG-gated spiral scans, respectively. Additionally, there was no effect of heart rate and acquisition mode on FWHM at diastole (p-values < 0.001). DSC demonstrated similarity among parameters with standard deviations of 0.08, 0.09, 0.11, and 0.08 for VMI 50, 70, and 150 keV, and iodine density maps, respectively, with insignificant differences at diastole (p-values < 0.01). Similarly, eccentricity illustrated small differences across heart rate and acquisition mode for each spectral result. Consistency of spectral results at different heart rates and acquisition modes for different cardiac phase demonstrates the added benefit of spectral results from PCCT to dual-source CT to further increase confidence in quantification and advance cardiovascular diagnostics.

Indexed as

Coronary StenosisIodineConstriction, PathologicHeartHumansRetrospective StudiesTomography, X-Ray ComputedIodine

Identifiers

PMID37689744
PMCPMC10492823

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.