ArticleScientific reports2023
Consistency of spectral results in cardiac dual-source photon-counting CT.
Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Mixed coronary plaque phantom analysis by photon-counting CT: impact of calcium and iodine on low-attenuation plaque detection.European heart journal. Imaging methods and practice · 2026Article
- Impact of vessel size, dose levels, and body habitus on iodine quantification in cardiovascular photon-counting computed tomography.The British journal of radiology · 2025Article
- Spectral Imaging Techniques in Heart Disease Assessment Using Photon-Counting Detector Computed Tomography.Echocardiography (Mount Kisco, N.Y.) · 2025Review
- Comparing Different Contrast Injection Methods for Multislice Spiral CT Imaging in Triple-Rule-Out Examinations: A Study on Acute Chest Pain Patients.International journal of general medicine · 2025Article
- Impact of technical, patient-related and measurement variables on serial Hounsfield unit-based quantitative coronary plaque analysis in computed tomography: time for a new chapter.European heart journal. Imaging methods and practice · 2025Review
- Deep Learning-Based Reconstruction Algorithm With Lung Enhancement Filter for Chest CT: Effect on Image Quality and Ground Glass Nodule Sharpness.Korean journal of radiology · 2024Article
- Accuracy of ultra-high resolution and virtual non-calcium reconstruction algorithm for stenosis evaluation with photon-counting CT: results from a dynamic phantom study.European radiology experimental · 2024Article
- Spectral quantification in different lumen diameters for cardiovascular applications.Conference proceedings. International Conference on Image Formation in X-Ray Computed Tomography · 2024Article
- Dual-Energy and Photon-Counting Computed Tomography in Vascular Applications-Technical Background and Post-Processing Techniques.Diagnostics (Basel, Switzerland) · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
We evaluate stability of spectral results at different heart rates, acquisition modes, and cardiac phases in first-generation clinical dual-source photon-counting CT (PCCT). A cardiac motion simulator with a coronary stenosis mimicking a 50% eccentric calcium plaque was scanned at five different heart rates (0, 60-100 bpm) with the three available cardiac scan modes (high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, retrospectively ECG-gated spiral). Subsequently, full width half max (FWHM) of the stenosis, Dice score (DSC) for the stenosed region, and eccentricity of the non-stenosed region were calculated for virtual monoenergetic images (VMI) at 50, 70, and 150 keV and iodine density maps at both diastole and systole. FWHM averaged differences of - 0.20, - 0.28, and - 0.15 mm relative to static FWHM at VMI 150 keV across acquisition parameters for high pitch prospectively ECG-triggered spiral, prospectively ECG-triggered axial, and retrospectively ECG-gated spiral scans, respectively. Additionally, there was no effect of heart rate and acquisition mode on FWHM at diastole (p-values < 0.001). DSC demonstrated similarity among parameters with standard deviations of 0.08, 0.09, 0.11, and 0.08 for VMI 50, 70, and 150 keV, and iodine density maps, respectively, with insignificant differences at diastole (p-values < 0.01). Similarly, eccentricity illustrated small differences across heart rate and acquisition mode for each spectral result. Consistency of spectral results at different heart rates and acquisition modes for different cardiac phase demonstrates the added benefit of spectral results from PCCT to dual-source CT to further increase confidence in quantification and advance cardiovascular diagnostics.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials