Evidence map›Paper›PMID 37688046›Full record

ArticleSensors (Basel, Switzerland)2023

Dual-Channel Stretchable, Self-Tuning, Liquid Metal Coils and Their Fabrication Techniques.

Elizaveta Motovilova, Terry Ching, Jana Vincent, James Shin, Ek Tsoon Tan, Victor Taracila, Fraser Robb, Michinao Hashimoto, Darryl B Sneag, Simone Angela Winkler

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. Article
  3. Adaptable, wearable, and stretchable coils: A review.Magnetic resonance in medicine · 2025
    Review
  4. Article
  5. Metamaterial-Enabled Hybrid Receive Coil for Enhanced Magnetic Resonance Imaging Capabilities.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Elizaveta MotovilovaDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
Terry ChingPillar of Engineering Product Development, Singapore University of Technology and Design, Singapore 487372, Singapore.ORCID 0000-0002-5747-2020
Jana VincentGE Healthcare, Aurora, OH 44202, USA.ORCID 0000-0002-2707-6000
James ShinDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.
Ek Tsoon TanDepartment of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021, USA.ORCID 0000-0003-2847-9378
Victor TaracilaGE Healthcare, Aurora, OH 44202, USA.
Fraser RobbGE Healthcare, Aurora, OH 44202, USA.
Michinao HashimotoPillar of Engineering Product Development, Singapore University of Technology and Design, Singapore 487372, Singapore.ORCID 0000-0002-9684-2354
Darryl B SneagDepartment of Radiology and Imaging, Hospital for Special Surgery, New York, NY 10021, USA.
Simone Angela WinklerDepartment of Radiology, Weill Cornell Medicine, New York, NY 10065, USA.

Funding

A Self-Tuning Liquid Metal Coil Conforming to Movement for High-Resolution Brachial Plexus MRIR01EB031820 · NIBIB · WEILL MEDICAL COLL OF CORNELL UNIV · PI BALLON, DOUGLAS J, SNEAG, DARRYL · 2022 to 2025
$2.8M
Human Connectome Mapping Using Ultra-High-Resolution MRI: A Technological PathwayR00EB024341 · NIBIB · WEILL MEDICAL COLL OF CORNELL UNIV · PI WINKLER, SIMONE ANGELA · 2019 to 2021
$726k
NIBIB NIH HHS R00 EB024341NIBIB NIH HHS R01 EB031820
6 · The paper itself

Abstract

Flexible and stretchable radiofrequency coils for magnetic resonance imaging represent an emerging and rapidly growing field. The main advantage of such coil designs is their conformal nature, enabling a closer anatomical fit, patient comfort, and freedom of movement. Previously, we demonstrated a proof-of-concept single element stretchable coil design with a self-tuning smart geometry. In this work, we evaluate the feasibility of scaling this coil concept to a multi-element coil array and the associated engineering and manufacturing challenges. To this goal, we study a dual-channel coil array using full-wave simulations, bench testing, in vitro, and in vivo imaging in a 3 T scanner. We use three fabrication techniques to manufacture dual-channel receive coil arrays: (1) single-layer casting, (2) double-layer casting, and (3) direct-ink-writing. All fabricated arrays perform equally well on the bench and produce similar sensitivity maps. The direct-ink-writing method is found to be the most advantageous fabrication technique for fabrication speed, accuracy, repeatability, and total coil array thickness (0.6 mm). Bench tests show excellent frequency stability of 128 ± 0.6 MHz (0% to 30% stretch). Compared to a commercial knee coil array, the stretchable coil array is more conformal to anatomy and provides 50% improved signal-to-noise ratio in the region of interest.

Indexed as

CommerceEngineeringHumansKnee JointMetalsMovementMetals3D printingdirect ink writingliquid metalradiofrequency coilself-tuningstretchable electronics

Identifiers

PMID37688046
PMCPMC10490642

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.