ArticleSensors (Basel, Switzerland)2023
Rectangular Amplitude Mask-Based Auto-Focus Method with a Large Range and High Precision for a Micro-LED Wafer Defects Detection System.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- A Rapid Nanofocusing Method for a Deep-Sea Gene Sequencing Microscope Based on Critical Illumination.Sensors (Basel, Switzerland) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Auto-focus technology plays an important role in the Micro-LED wafer defects detection system. How to accurately measure the defocus amount and the defocus direction of the Micro-LED wafer sample in a large linear range is one of the keys to realizing wafer defects detection. In this paper, a large range and high-precision auto-focus method based on a rectangular amplitude mask is proposed. A rectangular amplitude mask without a long edge is used to modulate the shape of the incident laser beams so that the spot shape distribution of the reflected laser beam on the sensor changes with the defocus amount of the wafer sample. By calculating the shape of the light spots, the defocus amount and the defocus direction can be obtained at the same time. The experimental results show that under the 20× microscopy objective, the linear range of the auto-focus system is 480 μm and the accuracy can reach 1 μm. It can be seen that the automatic focusing method proposed in this paper has the advantages of large linear range, high accuracy, and compact structure, which can meet the requirements of the Micro-LED wafer defects detection equipment.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.