Evidence map›Paper›PMID 37687980›Full record

ArticleSensors (Basel, Switzerland)2023

The Proper Use of Fibre-Optic Sensors to Monitor the Condition of the Steam Boiler Hanger Rods.

Magdalena Palacz, Bolesław Bąk, Łukasz Felkowski, Piotr Duda, Iliya Iliev

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Magdalena PalaczDepartment of Production Engineering, Faculty of Organisation and Management, Silesian University of Technology, Akademicka 2A, 44-100 Gliwice, Poland.ORCID 0000-0001-8369-5175
Bolesław BąkSumitomo SHI FW Energia Polska sp. z o.o., Młynarska 42, 01-171 Warszawa, Poland.
Łukasz FelkowskiInstitute of Thermal and Process Engineering, Cracow University of Technology, Al. Jana Pawła II 37, 31-864 Krakow, Poland.
Piotr DudaInstitute of Thermal and Process Engineering, Cracow University of Technology, Al. Jana Pawła II 37, 31-864 Krakow, Poland.ORCID 0000-0003-4043-7963
Iliya IlievDepartment of Heat, Hydraulics and Environmental Engineering, "Angel Kanchev" University of Ruse, 7017 Ruse, Bulgaria.ORCID 0000-0003-4443-5113

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fibre optic sensors with integrated Bragg gratings are widely used in the diagnostics of machinery and equipment. They achieved their popularity thanks to their relatively simple operating principles. In addition, they allow the continuous monitoring of several variable physical parameters of objects, such as strain or temperature change, which directly translates into immediate feedback regarding potential damage. However, despite the easy-to-understand operating principle, selecting a specific type for a particular application can be problematic. This article aims to present the process of selecting the optimal set of fibre-optic sensors with integrated Bragg grating, which can be used in the process of monitoring the stress state of hanger rods of an engineering object such as an industrial boiler. The hanger rods of such boilers require constant technical supervision; however, the current measurement methods do not provide an effective and non-invasive diagnostic method. Therefore, the authors have undertaken the task of developing a universal diagnostic strategy for hanger rods. To this end, they will present the results of an analysis of the applicability of FBGs, examples of the use of different types of sensors, their installation methods, and the technical capabilities of the equipment necessary to handle the signals recorded with these sensors. Exemplary results of strain measurements of a selected hanger rod performed by the traditional method used now and with a selected FBG fibre optic sensor will be presented. In conclusion, concrete technical suggestions will be presented to be implemented in the existing industrial facility during the next part of the study.

Indexed as

condition monitoringFBG sensorshanger rod

Identifiers

PMID37687980
PMCPMC10490651

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.