Evidence map›Paper›PMID 37687955›Full record

ArticleSensors (Basel, Switzerland)2023

Shoulder Range of Motion Measurement Using Inertial Measurement Unit-Concurrent Validity and Reliability.

Jakub Kaszyński, Cezary Baka, Martyna Białecka, Przemysław Lubiatowski

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jakub KaszyńskiRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.ORCID 0000-0001-5031-1227
Cezary BakaRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.ORCID 0000-0003-3539-6693
Martyna BiałeckaRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.ORCID 0000-0002-0409-3123
Przemysław LubiatowskiRehasport Clinic, Gorecka 30, 60-201 Poznan, Poland.ORCID 0000-0002-1011-981X

Funding

National Centre for Research and Development POIR.01.01.01-00-0837/17
6 · The paper itself

Abstract

This study aimed to evaluate the reliability of the RSQ Motion sensor and its validity against the Propriometer and electronic goniometer in measuring the active range of motion (ROM) of the shoulder. The study included 15 volunteers (mean age 24.73 ± 3.31) without any clinical symptoms with no history of trauma, disease, or surgery to the upper limb. Four movements were tested: flexion, abduction, external and internal rotation. Validation was assessed in the full range of active shoulder motion. Reliability was revised in full active ROM, a fixed angle of 90 degrees for flexion and abduction, and 45 degrees for internal and external rotation. Each participant was assessed three times: on the first day by both testers and on the second day only by one of the testers. Goniometer and RSQ Motion sensors showed moderate to excellent correlation for all tested movements (ICC 0.61-0.97, LOA < 23 degrees). Analysis of inter-rater reliability showed good to excellent agreement between both testers (ICC 0.74-0.97, LOA 13-35 degrees). Analysis of intra-rater reliability showed moderate to a good agreement (ICC 0.7-0.88, LOA 22-37 degrees). The shoulder internal and external rotation measurement with RSQ Motion sensors is valid and reliable. There is a high level of inter-rater and intra-rater reliability for the RSQ Motion sensors and Propriometer.

Indexed as

ShoulderUpper ExtremityAdultHumansRange of Motion, ArticularReproducibility of ResultsRotationYoung AdultIMUrange of motionshouldervalidationwearable movement sensors

Identifiers

PMID37687955
PMCPMC10490745

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.