Evidence map›Paper›PMID 37687835›Full record

ArticleSensors (Basel, Switzerland)2023

Optimization for Pipeline Corrosion Sensor Placement in Oil-Water Two-Phase Flow Using CFD Simulations and Genetic Algorithm.

Shuomang Shi, Baiyu Jiang, Simone Ludwig, Luyang Xu, Hao Wang, Ying Huang, Fei Yan

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Shuomang ShiDepartment of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58105, USA.
Baiyu JiangDepartment of Civil and Environmental Engineering, School of Engineering, Rutgers, The State University of New Jersey, New Brunswick, NJ 08901, USA.
Simone LudwigDepartment of Computer Science, North Dakota State University, Fargo, ND 58105, USA.ORCID 0000-0002-8419-0192
Luyang XuDepartment of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58105, USA.
Hao WangDepartment of Civil and Environmental Engineering, School of Engineering, Rutgers, The State University of New Jersey, New Brunswick, NJ 08901, USA.ORCID 0000-0001-8666-6900
Ying HuangDepartment of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58105, USA.
Fei YanDepartment of Civil, Construction, and Environmental Engineering, North Dakota State University, Fargo, ND 58105, USA.
North Dakota State University · USRutgers, The State University of New Jersey · US

Funding

National Science Foundation OIA-2119691U. S. Department of Transportation Pipeline and Hazardous Materials Safety Admin-istration (PHMSA) 693JK31850008CAAP
6 · The paper itself

Abstract

Internal corrosion is a major concern in ensuring the safety of transmission and gathering pipelines in Structural Health Monitoring (SHM). It usually requires numerous sensors deployed inside the piping system to comprehensively cover the locations with high corrosion rates. This study presents a hybrid modeling strategy using Computational Fluid Dynamics (CFD) and Genetic Algorithm (GA) to improve the sensor placement scheme for corrosion detection and monitoring. The essence of the proposed strategy harnesses the well-validated physical modeling capability of the CFD to simulate the oil-water two-phase flow and the stochastic searching ability of the GA to explore better solutions on a global level. The CFD-based corrosion rate prediction was validated through experimental results and further used to form the initial population for GA optimization. Importantly, fitness was defined by considering both sensing effectiveness and cost of sensor coverage. The hybrid modeling strategy was implemented through case studies, where three typical pipe fittings were used to demonstrate the applicability of the sensor layout design for corrosion detection in pipelines. The GA optimization results show high accuracy for sensor placement inside the pipelines. The best fitness of the U-shaped, upward-inclined, and downward-inclined pipes were 0.9415, 0.9064, and 0.9183, respectively. Upon this, the hybrid modeling strategy can provide a promising tool for the pipeline industry to design the practical placement.

Indexed as

Computational Fluid Dynamics (CFD)corrosionGenetic Algorithm (GA)pipelinesStructural Health Monitoring (SHM)

Identifiers

PMID37687835
PMCPMC10490490
OpenAlexW4386141780

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.