ArticleSensors (Basel, Switzerland)2023
Measurement Accuracy of the HTC VIVE Tracker 3.0 Compared to Vicon System for Generating Valid Positional Feedback in Virtual Reality.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 23 citations in OpenAlex.
- Feedback-Enhanced Virtual Reality Upper-Limb Training With Body Position Measurement in Healthy Adults: Development and Validation Study.JMIR formative research · 2026Article
- Altering sensory cues for spatial navigation does not impose a dual-task effect on gait and balance.Experimental brain research · 2026Article
- Altering sensory cues for spatial navigation does not impose a dual-task effect on gait and balance.bioRxiv : the preprint server for biology · 2026Article
- Interpretable Biomechanical Feature Selection for VR Exercise Assessment Using SHAP and LDA.Sensors (Basel, Switzerland) · 2026Article
- Development of Control Algorithms for an Adaptive Running Platform for a Musculoskeletal Rehabilitation System.Sensors (Basel, Switzerland) · 2025Article
- Comparing object lifting kinematics and the size-weight illusion between physical reality and virtual reality.Attention, perception & psychophysics · 2025Article
- Squat Kinematics Analysis Using Vicon and Affordable Motion-Capture Solutions.Sensors (Basel, Switzerland) · 2025Article
- Virtual reality-enhanced rehabilitation for improving musculoskeletal function and recovery after trauma.Journal of orthopaedic surgery and research · 2025Review
- Manipulation of interpersonal synchrony in psychotherapy using extended reality: Mapping future directions.International journal of clinical and health psychology : IJCHPArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
For realistic and reliable full-body visualization in virtual reality, the HTC VIVE Tracker could be an alternative to highly complex and cost- and effort-intensive motion capture systems such as Vicon. Due to its lighter weight and smaller dimensions, the latest generation of trackers is proving to be very promising for capturing human movements. The aim of this study was to investigate the accuracy of the HTC VIVE Tracker 3.0 compared to the gold-standard Vicon for different arrangements of the base stations and various velocities during an athletic movement. Therefore, the position data from three trackers attached to the hip, knee and ankle of one sporty participant were recorded while riding a bicycle ergometer at different pedaling frequencies and different base station arrangements. As parameters for the measurement accuracy, the trajectories of the linear motion of the knee and the circular motion of the ankle were compared between VIVE and Vicon by calculating the spatial distance from the raw data at each point in time. Both the pedaling frequency and the arrangement of the base stations significantly affected the measurement accuracy, with the lowest pedaling frequency of 80 rpm and the rectangular arrangement recommended by the manufacturer showing the smallest spatial differences of 10.4 mm ± 4.5 mm at the knee and 11.3 mm ± 5.1 mm at the ankle. As the pedaling frequency increased gradually (120 rpm and 160 rpm), the measurement accuracy of the trackers per step decreased less at the knee (approximately 5 mm) than at the ankle (approximately 10 mm). In conclusion, the measurement accuracy for various athletic skills was high enough to enable the visualization of body limbs or the entire body using inverse kinematics in VR on the one hand and, on the other hand, to provide initial insights into the quality of certain techniques at lower speeds in sports science research. However, the VIVE trackers are not suitable for exact biomechanical analyses.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.