Evidence map›Paper›PMID 37687782›Full record

ArticleSensors (Basel, Switzerland)2023

Low-Pass Filters for a Temperature Drift Correction Method for Electromagnetic Induction Systems.

Martial Tazifor Tchantcho, Egon Zimmermann, Johan Alexander Huisman, Markus Dick, Achim Mester, Stefan van Waasen

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Martial Tazifor TchantchoCentral Institute of Engineering, Electronics and Analytics (ZEA-2), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany.ORCID 0000-0001-5868-4466
Egon ZimmermannCentral Institute of Engineering, Electronics and Analytics (ZEA-2), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany.ORCID 0000-0003-1517-6597
Johan Alexander HuismanInstitute of Bio- and Geosciences Agrosphere (IBG-3), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany.ORCID 0000-0002-1327-0945
Markus DickCentral Institute of Engineering, Electronics and Analytics (ZEA-2), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany.ORCID 0000-0001-9278-4583
Achim MesterCentral Institute of Engineering, Electronics and Analytics (ZEA-2), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany.ORCID 0000-0002-1587-8516
Stefan van WaasenCentral Institute of Engineering, Electronics and Analytics (ZEA-2), Forschungszentrum Juelich GmbH, 52428 Juelich, Germany.ORCID 0000-0003-0682-7941

Funding

Deutsche Forschungsgemeinschaft EXC-2070 - 390732324 - PhenoRob
6 · The paper itself

Abstract

Electromagnetic induction (EMI) systems are used for mapping the soil's electrical conductivity in near-surface applications. EMI measurements are commonly affected by time-varying external environmental factors, with temperature fluctuations being a big contributing factor. This makes it challenging to obtain stable and reliable data from EMI measurements. To mitigate these temperature drift effects, it is customary to perform a temperature drift calibration of the instrument in a temperature-controlled environment. This involves recording the apparent electrical conductivity (ECa) values at specific temperatures to obtain a look-up table that can subsequently be used for static ECa drift correction. However, static drift correction does not account for the delayed thermal variations of the system components, which affects the accuracy of drift correction. Here, a drift correction approach is presented that accounts for delayed thermal variations of EMI system components using two low-pass filters (LPF). Scenarios with uniform and non-uniform temperature distributions in the measurement device are both considered. The approach is developed using a total of 15 measurements with a custom-made EMI device in a wide range of temperature conditions ranging from 10 °C to 50 °C. The EMI device is equipped with eight temperature sensors spread across the device that simultaneously measure the internal ambient temperature during measurements. To parameterize the proposed correction approach, a global optimization algorithm called Shuffled Complex Evolution (SCE-UA) was used for efficient estimation of the calibration parameters. Using the presented drift model to perform corrections for each individual measurement resulted in a root mean square error (RMSE) of <1 mSm

Indexed as

apparent electrical conductivity (ECa)electromagnetic induction (EMI)temperature drift correction

Identifiers

PMID37687782
PMCPMC10489996

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.