Evidence map›Paper›PMID 37685385›Full record

ArticleDiagnostics (Basel, Switzerland)2023

Age Matters: A Comparative Study of RF Heating of Epicardial and Endocardial Electronic Devices in Pediatric and Adult Phantoms during Cardiothoracic MRI.

Fuchang Jiang, Kaylee R Henry, Bhumi Bhusal, Pia Sanpitak, Gregory Webster, Andrada Popescu, Christina Laternser, Daniel Kim, Laleh Golestanirad

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Fuchang JiangDepartment of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA.
Kaylee R HenryDepartment of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA.ORCID 0000-0002-3003-9681
Bhumi BhusalDepartment of Radiology, Northwestern University, Chicago, IL 60611, USA.
Pia SanpitakDepartment of Radiology, Northwestern University, Chicago, IL 60611, USA.
Gregory WebsterDivision of Cardiology, Ann and Robert H. Lurie Children's Hospital of Chicago, Northwestern University, Chicago, IL 60611, USA.
Andrada PopescuDivision of Medical Imaging, Ann and Robert H. Lurie Children's Hospital of Chicago, Northwestern University, Chicago, IL 60611, USA.
Christina LaternserDivision of Cardiology, Ann and Robert H. Lurie Children's Hospital of Chicago, Northwestern University, Chicago, IL 60611, USA.ORCID 0000-0003-0336-3547
Daniel KimDepartment of Radiology, Northwestern University, Chicago, IL 60611, USA.
Laleh GolestaniradDepartment of Biomedical Engineering, Northwestern University, Evanston, IL 60208, USA.

Funding

Reconfigurable MRI technology for safe and high-resolution imaging of deep brain stimulation at 3TR01EB030324 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI GOLESTANI RAD, LALEH · 2021 to 2024
$2.1M
Novel MRI coil technology for safe imaging of children with implantsR01EB034377 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI GOLESTANI RAD, LALEH · 2023 to 2025
$1.5M
NIBIB NIH HHS R01 EB034377NIH HHS R01EB030324
6 · The paper itself

Abstract

This study focused on the potential risks of radiofrequency-induced heating of cardiac implantable electronic devices (CIEDs) in children and adults with epicardial and endocardial leads of varying lengths during cardiothoracic MRI scans. Infants and young children are the primary recipients of epicardial CIEDs, though the devices have not been approved as MR conditional by the FDA due to limited data, leading to pediatric hospitals either refusing the MRI service to most pediatric CIED patients or adopting a scan-all strategy based on results from adult studies. The study argues that risk-benefit decisions should be made on an individual basis. We used 120 clinically relevant epicardial and endocardial device configurations in adult and pediatric anthropomorphic phantoms to determine the temperature rise during RF exposure at 1.5 T. The results showed that there was significantly higher RF heating of epicardial leads than endocardial leads in the pediatric phantom, but not in the adult phantom. Additionally, body size and lead length significantly affected RF heating, with RF heating up to 12 °C observed in models based on younger children with short epicardial leads. The study provides evidence-based knowledge on RF-induced heating of CIEDs and highlights the importance of making individual risk-benefit decisions when assessing the potential risks of MRI scans in pediatric CIED patients.

Indexed as

cardiacepicardial leadsimagingimplantsMRIpediatricsafety

Identifiers

PMID37685385
PMCPMC10486594

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.