ArticlePhysical therapy2024
Accuracy of Video-Based Gait Analysis Using Pose Estimation During Treadmill Walking Versus Overground Walking in Persons After Stroke.
Article in Physical therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 13 citations in OpenAlex.
- Effect of Upper Limb Repetitive Facilitative Exercise on Gait of Stroke Patients based on Artificial Intelligence and Computer Vision Evaluation.Journal of musculoskeletal & neuronal interactions · 2024Trial
- Artificial Intelligence in Physical Therapy: A Narrative Review of Artificial Intelligence Applications Across the Patient and Client Management Model.Health science reports · 2026Article
- Validation of AI-based markerless gait event detection during perturbed walking using smartphone videos from two camera perspectives.Frontiers in sports and active living · 2026Article
- A graphical user interface for editing keypoints from human pose estimation algorithms.medRxiv : the preprint server for health sciences · 2025Article
- Validation of markerless video-based gait analysis using pose estimation in toddlers with and without neurodevelopmental disorders.Frontiers in digital health · 2025Article
- Quantifying Arm and Leg Movements in 3-Month-Old Infants Using Pose Estimation: Proof of Concept.Sensors (Basel, Switzerland) · 2024Article
- Integrated software for multi-dimensional analysis of motion using tracking, electrophysiology, and sensor signals.Frontiers in bioengineering and biotechnology · 2023Article
Corrections and comments
- Erratum issued
Authors and funding
9 authors at 5 institutions in 1 country.
Funding
Abstract
objectiveVideo-based pose estimation is an emerging technology that shows significant promise for improving clinical gait analysis by enabling quantitative movement analysis with little costs of money, time, or effort. The objective of this study is to determine the accuracy of pose estimation-based gait analysis when video recordings are constrained to 3 common clinical or in-home settings (ie, frontal and sagittal views of overground walking and sagittal views of treadmill walking).
methodsSimultaneous video and motion capture recordings were collected from 30 persons after stroke during overground and treadmill walking. Spatiotemporal and kinematic gait parameters were calculated from videos using an open-source human pose estimation algorithm and from motion capture data using traditional gait analysis. Repeated-measures analyses of variance were then used to assess the accuracy of the pose estimation-based gait analysis across the different settings, and the authors examined Pearson and intraclass correlations with ground-truth motion capture data.
resultsSagittal videos of overground and treadmill walking led to more accurate measurements of spatiotemporal gait parameters versus frontal videos of overground walking. Sagittal videos of overground walking resulted in the strongest correlations between video-based and motion capture measurements of lower extremity joint kinematics. Video-based measurements of hip and knee kinematics showed stronger correlations with motion capture versus ankle kinematics for both overground and treadmill walking.
conclusionVideo-based gait analysis using pose estimation provides accurate measurements of step length, step time, and hip and knee kinematics during overground and treadmill walking in persons after stroke. Generally, sagittal videos of overground gait provide the most accurate results. IMPACT: Many clinicians lack access to expensive gait analysis tools that can help identify patient-specific gait deviations and guide therapy decisions. These findings show that video-based methods that require only common household devices provide accurate measurements of a variety of gait parameters in persons after stroke and could make quantitative gait analysis significantly more accessible.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.