Evidence map›Paper›PMID 37680263›Full record

ArticleFrontiers in surgery2023

Evaluation of the mechanical properties and clinical application of nickel-titanium shape memory alloy anal fistula clip.

Heng Deng, Ming Li, Xiaoli Fang, Jun Zhang, Jianmin Wang, Kun Tang, Ran Tang, Ru Jia, Ying Han, Yang Shi and 1 more

Open access · goldAbstract read
In one paragraph

Article in Frontiers in surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

11 authors at 3 institutions in 1 country.

Heng DengDepartment of Anorectal Surgery, Second Affiliated Hospital of Anhui University of Chinese Medicine, Hefei, China.
Ming LiDepartment of Anorectal Surgery, First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, China.
Xiaoli FangDepartment of Anorectal Surgery, First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, China.
Jun ZhangCollege of Traditional Chinese Medicine, Anhui University of Chinese Medicine, Hefei, China.
Jianmin WangDepartment of Anorectal Surgery, First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, China.
Kun TangDepartment of Anorectal Surgery, First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, China.
Ran TangDepartment of Anorectal Surgery, First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, China.
Ru JiaDepartment of Anorectal Surgery, Second Affiliated Hospital of Anhui University of Chinese Medicine, Hefei, China.
Ying HanDepartment of Anorectal Surgery, First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, China.
Yang ShiDepartment of Anorectal Surgery, First Affiliated Hospital of Anhui University of Traditional Chinese Medicine, Hefei, China.
Yu'ang DongCollege of Traditional Chinese Medicine, Anhui University of Chinese Medicine, Hefei, China.
Anhui University of Traditional Chinese Medicine · CNAnhui Medical University · CNSecond Hospital of Anhui Medical University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: The study investigates the mechanical properties of a nickel-titanium shape memory alloy anal fistula clip (NiTi-AFC), studies the surgical method of treating anal fistula, and evaluates its clinical efficacy. Methods: The anal fistula clip was formed in nickel-titanium alloy with a titanium content of 50.0%-51.8%. The mechanical properties and chemical properties were tested. A total of 31 patients with anal fistula were enrolled between 1 January 2020 and 1 January 2023. All patients underwent internal orifice closure surgery using NiTi-AFC, and anorectal magnetic resonance or ultrasound was performed before surgery and 6 months after surgery for diagnosis and evaluation. Fistula cure rates, length of stay, perianal pain, and Wexner incontinence scores were retrospectively compared between patients treated with NiTi-AFC and patients treated with other surgical methods. Result: NiTi-AFC has a density of 6.44-6.50 g·cm Conclusion: NiTi-AFC has shape memory properties, corrosion resistance, superelastic effect, and surface cell adhesion. It is applied to internal orifice closure surgery of anal fistula, with good therapeutic effect, and can protect the anal function.

Indexed as

anal fistula clipclinical applicationinternal orificemechanical propertiesnickel–titanium alloy

Identifiers

PMID37680263
PMCPMC10481869
OpenAlexW4386091055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.