Evidence map›Paper›PMID 37679969›Full record

ArticleJournal of applied clinical medical physics2023

Dosimetric evaluation of a spinal cord dose-limiting 3D-CRT technique for radiotherapy of spinal metastases.

Christian Cornelius Arnold, André Toussaint, Frederick Mantel, Michael Flentje, Klaus Bratengeier

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Christian Cornelius ArnoldDepartment of Radiotherapy and Oncology, Goethe University Frankfurt, Frankfurt, Germany.ORCID https://orcid.org/0000-0001-7420-8953
André ToussaintDepartment of Radiation Oncology, University of Wuerzburg, Wuerzburg, Germany.
Frederick MantelDepartment of Radiation Oncology, University of Wuerzburg, Wuerzburg, Germany.
Michael FlentjeDepartment of Radiation Oncology, University of Wuerzburg, Wuerzburg, Germany.
Klaus BratengeierDepartment of Radiation Oncology, University of Wuerzburg, Wuerzburg, Germany.ORCID https://orcid.org/0000-0002-3840-7952

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo evaluate the possible advantages of a simple spinal cord (SC) dose-limiting three-dimensional conformal radiotherapy (3D-CRT) technique in comparison to conventional two-dimensional (2D) techniques and other 3D-CRT techniques for spinal bone irradiation.

methodsFor 41 spinal target volumes, seven different techniques were evaluated, using a standard schedule of 30 Gy in 10 fractions. The SC dose-limiting 3D-CRT technique 1F2S-18MV using a single posterior field (F) supplemented by two anterior segment fields (S) and 18-MV photon beams was compared to two conventional 2D techniques (a single posterior field, PA, and two opposed anterior-posterior fields, APPA), three other 3D-CRT techniques (a single posterior field supplemented by four segment fields, 1F4S; two wedged fields, WD, and the SC dose-limiting variant using 6 MV, 1F2S-6MV) along with the original clinically applied plans.

results1F2S-18MV demonstrated notably better results for all target volume parameters compared to the conventional 2D techniques (p < 0.001). Limitation of the SC dose was significantly superior with 1F2S-18MV in comparison to PA and APPA (SC Dmean: 28.9 ± 0.4  vs. 30.1 ± 0.6 Gy and 30.1 ± 0.4 Gy; SC Dmax: 30.9 ± 0.7  vs. 32.5 ± 1.0 Gy and 31.8 ± 0.7 Gy; SC D1cm

conclusionIn treatment planning of spinal metastases, simple variants of 3D-CRT-techniques like 1F2S-18MV can offer a significant dose limitation to the SC while providing a sufficient dose coverage of the target volume. Especially in patients with favorable life expectancy and potential need for re-irradiation, such SC dose-limiting 3D-CRT techniques may be a reasonable approach.

Indexed as

Radiotherapy, ConformalRadiotherapy, Intensity-ModulatedSpinal NeoplasmsHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedSpinal Cord3D-CRTpalliative radiotherapyplanning studyre-irradiationspinal metastases

Identifiers

PMID37679969
PMCPMC10562034

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.