Evidence map›Paper›PMID 37676923›Full record

ArticleMagnetic resonance in medicine2024

Real-time automatic image-based slice tracking of gadolinium-filled balloon wedge catheter during MR-guided cardiac catheterization: A proof-of-concept study.

Rohini Vidya Shankar, Li Huang, Radhouene Neji, Grzegorz Kowalik, Alexander Paul Neofytou, Ronald Mooiweer, Tracy Moon, Nina Mellor, Reza Razavi, Kuberan Pushparajah and 1 more

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Rohini Vidya ShankarBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0003-0762-7052
Li HuangBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0002-3657-0799
Radhouene NejiBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0002-6543-4390
Grzegorz KowalikBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0003-3267-8652
Alexander Paul NeofytouBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0002-8488-3925
Ronald MooiweerBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0003-2693-1033
Tracy MoonGuy's and St Thomas' NHS Foundation Trust, London, UK.
Nina MellorGuy's and St Thomas' NHS Foundation Trust, London, UK.
Reza RazaviBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0003-1065-3008
Kuberan PushparajahBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0003-1541-1155
Sébastien RoujolBiomedical Engineering Department, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.ORCID 0000-0002-7146-0552

Funding

British Heart Foundation PG/19/11/34243British Heart Foundation PG/21/10539Wellcome TrustWellcome Trust WT 203148/Z/16/Z
6 · The paper itself

Abstract

purposeMR-guided cardiac catheterization procedures currently use passive tracking approaches to follow a gadolinium-filled catheter balloon during catheter navigation. This requires frequent manual tracking and repositioning of the imaging slice during navigation. In this study, a novel framework for automatic real-time catheter tracking during MR-guided cardiac catheterization is presented.

methodsThe proposed framework includes two imaging modes (Calibration and Runtime). The sequence starts in Calibration mode, in which the 3D catheter coordinates are determined using a stack of 10-20 contiguous saturated slices combined with real-time image processing. The sequence then automatically switches to Runtime mode, where three contiguous slices (acquired with partial saturation), initially centered on the catheter balloon using the Calibration feedback, are acquired continuously. The 3D catheter balloon coordinates are estimated in real time from each Runtime slice stack using image processing. Each Runtime stack is repositioned to maintain the catheter balloon in the central slice based on the prior Runtime feedback. The sequence switches back to Calibration mode if the catheter is not detected. This framework was evaluated in a heart phantom and 3 patients undergoing MR-guided cardiac catheterization. Catheter detection accuracy and rate of catheter visibility were evaluated.

resultsThe automatic detection accuracy for the catheter balloon during the Calibration/Runtime mode was 100%/95% in phantom and 100%/97 ± 3% in patients. During Runtime, the catheter was visible in 82% and 98 ± 2% of the real-time measurements in the phantom and patients, respectively.

conclusionThe proposed framework enabled real-time continuous automatic tracking of a gadolinium-filled catheter balloon during MR-guided cardiac catheterization.

Indexed as

Cardiac CatheterizationGadoliniumCathetersHeartHumansPhantoms, ImagingGadoliniumcardiac catheterizationimage processingMR guidancepartial saturationpassive trackingreal time

Identifiers

PMID37676923
PMCPMC10952810

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked