Investigating the impact of breast positioning control on physical treatment parameters in multi-catheter breast brachytherapy.

Andre Karius, Vratislav Strnad, Michael Lotter, Stephan Kreppner, Rainer Fietkau, Christoph Bert

Open access · hybridAbstract read
In one paragraph

Article in Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al], 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Is model-based dose calculation based on cone-beam computed tomography suitable for adaptive treatment planning in brachytherapy?Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Andre KariusDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany. andre.karius@uk-erlangen.de.ORCID 0000-0002-3842-1375
Vratislav StrnadDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Michael LotterDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Stephan KreppnerDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Rainer FietkauDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Christoph BertDepartment of Radiation Oncology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg, Universitätsstr. 27, 91054, Erlangen, Germany.
Friedrich-Alexander-Universität Erlangen-Nürnberg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo assess the effects of a workflow for reproducible patient and breast positioning on implant stability during high-dose-rate multi-catheter breast brachytherapy.

methodsThirty patients were treated with our new positioning control workflow. Implant stability was evaluated based on a comparison of planning-CTs to control-CTs acquired halfway through the treatment. To assess geometric stability, button-button distance variations as well as Euclidean dwell position deviations were evaluated. The latter were also quantified within various separated regions within the breast to investigate the location-dependency of implant alterations. Furthermore, dosimetric variations to target volume and organs at risk (ribs, skin) as well as isodose volume changes were analyzed. Results were compared to a previously treated cohort of 100 patients.

resultsWith the introduced workflow, the patient fraction affected by button-button distance variations > 5 mm and by dwell position deviations > 7 mm were reduced from 37% to 10% and from 30% to 6.6%, respectively. Implant stability improved the most in the lateral to medial breast regions. Only small stability enhancements were observed regarding target volume dosimetry, but the stability of organ at risk exposure became substantially higher. D

conclusionBreast positioning control improved geometric and dosimetric implant stability for individual patients, and thus enhanced physical plan validity in these cases.

Indexed as

BrachytherapyBreast NeoplasmsCathetersFemaleHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedAdaptive brachytherapyComputed tomographyImplant stabilityTreatment qualityTreatment re-planning

Identifiers

PMID37676482
PMCPMC10784386
OpenAlexW4386507611

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390