Evidence map›Paper›PMID 37672101›Full record

Trial reportGraefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2024

Comparison of clinical outcome after implantation of two toric intraocular lenses with different haptic type: a prospective randomized controlled trial.

Jiajun Sun, Huiran Bai, Wei Cui, Xiaoming Wu

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jiajun SunDepartment of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People's Republic of China.
Huiran BaiDepartment of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People's Republic of China.
Wei CuiDepartment of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People's Republic of China.
Xiaoming WuDepartment of Ophthalmology, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People's Republic of China. wuxiaominglmm@126.com.ORCID http://orcid.org/0000-0002-3664-8760

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo study the effect of astigmatism correction, rotational stability, and related factors of two different haptic type toric intraocular lenses.

methodsA prospective, randomized, controlled trial. Cataract patients with preoperative corneal astigmatism of > 1 D were randomly implanted with C-loop haptic toric IOL (AcrySof-toric IOL) (group A) or plate-haptic toric IOL (AT TORBI 709 M IOL) (group B). The residual astigmatism, intraocular lens rotation, and visual quality were determined and compared between the two groups at 3 months after surgery.

resultsSeventy-nine eyes were included in this study, including 40 eyes in the group A and 39 eyes in the group B. No significant difference in preoperative visual acuity, intraocular pressure, and ophthalmic biological parameters was found between the two groups. There was no significant difference in residual astigmatism between the two groups at 3 months after surgery (P > 0.05). The rotation degree in the group A was 3.85 ± 2.92°, the rotation degree in the group B was 2.33 ± 2.31°, and a significant difference in intraocular lens rotation was identified between the two groups (P < 0.05). Upon exploring the rotation-related factors of the two different haptic type toric intraocular lenses, the rotation after implanting C-loop haptic toric IOL was positively correlated with axial length (Pearson r = 0.522, P = 0.01) and corneal white-to-white distance (Pearson correlation analysis r = 0.356, P = 0.024).

conclusionsThe two different haptic type toric intraocular lenses effectively corrected regular corneal astigmatism and provided a good rotational stability after surgery. But the stability of plate-haptic toric IOL was better than that of C-loop haptic toric IOL. The rotational stability of C-loop haptic toric IOL was often related to axial length and corneal white-to-white distance.

Indexed as

AstigmatismCorneal DiseasesLenses, IntraocularCorneaHaptic TechnologyHumansProspective StudiesAstigmatismCataractC-loop hapticPlate-hapticRotational stabilityToric IOL

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.