Evidence map›Paper›PMID 37670446›Full record

ArticleActa orthopaedica et traumatologica turcica2023

Intraoperative fluoroscopic safety assessment of femoral head implants with 3-dimensional risk parameters to minimize cut-out.

Ömer Subaşı, Lercan Aslan, Atacan Oral, Mehmet Demirhan, Aksel Seyahi, İsmail Lazoğlu

Open access · goldAbstract read
In one paragraph

Article in Acta orthopaedica et traumatologica turcica, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 74% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Ömer SubaşıManufacturing and Automation Research Center, Koç University, Istanbul, Turkey.
Lercan AslanDepartment of Orthopaedics and Traumatology, Koç University Hospital, Istanbul, Turkey.
Atacan OralManufacturing and Automation Research Center, Koç University, Istanbul, Turkey.
Mehmet DemirhanDepartment of Orthopaedics and Traumatology, Koç University Hospital, Istanbul, Turkey.
Aksel SeyahiDepartment of Orthopaedics and Traumatology, Koç University Hospital, Istanbul, Turkey.
İsmail LazoğluManufacturing and Automation Research Center, Koç University, Istanbul, Turkey.
Koç University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveThis study aimed to introduce a method to extract the 3-dimensional spatial position of the femoral head implant from 2-dimensional fluoroscopic projections, allowing surgeons to assess fixation much more accurately and prevent cut-out complications in proximal femoral nailing.

methodsTo define a safety region for the tip in the femoral head, a novel 3-dimensional distance-based risk parameter called TSD3D was introduced. An intersection algorithm was developed that solely takes the fluoroscopic anteroposterior and lateral distances to reveal the 3-dimensional location of the screw or Kirschner wire tip, enabling the utilization of the 3-dimensional parameter. Orthogonal per- spectives of 6 femur proximal bone substitutes with randomly inserted Kirschner wires were imaged under fluoroscopy. The developed algorithm was used to calculate the implant tip location in 3-dimensional from 2-dimensional images for each case. Algorithm accuracy was validated with the computed tomography-obtained 3-dimensional models of the same femur substitutes.

resultsThe newly introduced risk parameter successfully visualizes 3-dimensional safety regions. Utilizing the 2-dimensional fluoro- scopic distances as inputs to the algorithm, the 3-dimensional position of the implanted Kirschner wire tip is calculated with a maximum of 9.8% error for a single Cartesian-coordinate measurement comparison.

conclusionBy incorporating the newly introduced 3-dimensional risk parameter, surgeons can more precisely evaluate the position of the implant and avoid cut-out complications, instead of relying solely on misleading 2-dimensional fluoroscopic projections of the femoral head.

Indexed as

Femur HeadSurgeonsBone ScrewsFemurFluoroscopyHumans

Identifiers

PMID37670446
PMCPMC10542487
OpenAlexW4386377166

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.