Evidence map›Paper›PMID 37670190›Full record

ArticleSurgical endoscopy2023

Learning curves and procedural times in Senhance®-robotic assisted fundoplication: results from 237 consecutive patients undergoing robotic fundoplication in a single center as part of the European TRUST Robotic Surgery Registry Study.

Vivianda Menke, Tanja Kottmann, Frank Willeke, Olaf Hansen

Abstract read
PubMed Publisher
In one paragraph

Article in Surgical endoscopy, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Vivianda MenkeAllgemeinchirurgie, Evangelisches Krankenhaus Wesel GmbH, Schermbecker Landstraße 88, 46485, Wesel, Germany. vivianda.menke@evkwesel.de.ORCID 0000-0002-2178-9683
Tanja KottmannCRO Dr. Kottmann GmbH& Co.KG, Hamm, Germany.
Frank WillekeThe TRUST European Registry Working Group, Siegen, Germany.
Olaf HansenAllgemeinchirurgie, Evangelisches Krankenhaus Wesel GmbH, Schermbecker Landstraße 88, 46485, Wesel, Germany.
Folkwang University of the Arts · DEUniversity of Siegen · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundGastroesophageal reflux disease requiring an operative solution is common. Minimally invasive surgery to generate an anti-reflux barrier at the distal esophagus following the principle of the "floppy Nissen" technique has become the gold standard. Advanced robotic-assisted systems may deliver more consisted outcomes.

methodsThis registry study analyzed safety and efficacy of the Senhance® surgical system in the surgical treatment of reflux disease and procedural proficiency. Data from 237 consecutive patients operated in a single center were evaluated. Historic standard laparoscopies from the same center were analyzed to compare robotic surgery learning curve effects.

resultsUsing the Senhance® Surgical System, during the first 50 patients there was a significant decrease in surgery time which was maintained over the duration of study, pointing to the surgical staff's system-specific learning. After this phase, procedural times were comparable between the robotic-assisted and traditional laparoscopic surgery. The effect of learning was greater than for standard laparoscopy. For 237 patients, there were four conversions to laparoscopic surgery. Two serious adverse events were recorded, both cardiac in nature and not related to the use of the robot.

conclusionsRobotic fundoplication was swiftly implemented in a non-university hospital with 65 surgical beds. The operating time was no longer than in standard laparoscopy, the procedure was more standardized than open or laparoscopic surgery and hospitalization times may have been sustainably shortened. The autonomy at the system's digital platform (cockpit) to conduct robotic fundoplications is a big step forward in surgery.

Indexed as

Gastroesophageal RefluxLaparoscopyRoboticsRobotic Surgical ProceduresFundoplicationHumansLearning CurveRegistriesTreatment OutcomeFundoplicationGastroesophageal reflux diseaseSurgical robotic system

Identifiers

PMID37670190
OpenAlexW4386448482

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked