ArticlePediatric cardiology2024
Low Risk of Inappropriate Shock Among Pediatric Patients With an Implantable Cardioverter Defibrillator: A Single Center Experience.
Article in Pediatric cardiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 3 citations in OpenAlex.
- Caution in Interpreting the Absence of Appropriate ICD Therapies in Pediatric Primary Prevention.Journal of arrhythmia · 2026Article
- Outcomes for patients implanted with a cardioverter-defibrillator at <19 years of age: a Swedish national study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026Article
- Evolution of implantable cardioverter-defibrillator shock therapy in children in the era of optimized ICD programming and remote monitoring.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Implantable cardioverter-defibrillators (ICD) are increasingly being used among the pediatric population for indications of both primary and secondary prevention. There is limited long-term data on the outcomes of pediatric patients following ICD implantation. The aim of this study was to investigate the characteristics of this population, burden of appropriate and inappropriate shock and complication rate in a large tertiary pediatric medical center. Included were children under the age of 18 years who underwent ICD implantation and had clinical follow up at our center. Data were retrospectively collected between study period 2005-2020. Primary outcome was the incidence of ICD shock appropriate and inappropriate. Secondary outcome was defining our patient population characteristics. Our cohort included 51 patients who underwent ICD implantation. Mean age at implantation was 10.9 ± 4.7 years and average follow-up time was 67 months. Diagnoses of implanted patients were: 28 (55%) patients with syndromes with risk for sudden death, cardiomyopathy in 14 patients (27%) and congenital heart disease (CHD) in 9 patients (18%). Forty-two (82%) patients had an ICD implanted for secondary prevention after experiencing a life-threatening arrhythmia and 9 (18%) for primary prevention. An endocardial system was implanted in 39 (76%) patients and an epicardial systems in 12 (24%) patients. A total of 20 (39%) patients received appropriate shocks for ventricular fibrillation(VF). 5 patients received inappropriate shocks, 4 due to sinus tachycardia and 1 due to rapidly conducted atrial fibrillation. Those who received an inappropriate shock had a significantly shorter ICD-programmed VF detection cycle length compared to those who did not receive an inappropriate shock (320 ms versus 270 ms, p = 0.062). This single center study demonstrates a high rate of appropriate ICD shocks (39%) and a low rate of inappropriate ICD shocks. Accurate programming of ICD devices in the pediatric population is paramount to avoid inappropriate ICD shocks.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.