ArticleInvestigative and clinical urology2023

Radiation exposure during different percutaneous renal puncture techniques: A YAU endourology & urolithiasis study.

Tarik Emre Sener, Yiloren Tanidir, Serap Ketenci, Umut Kutukoglu, Dogancan Dorucu, Huseyin Cayir, Amelia Pietropaolo, Esteban Emiliani, Bhaskar Somani

Open access · diamondAbstract read
In one paragraph

Article in Investigative and clinical urology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Trial
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 4 countries.

Tarik Emre SenerDepartment of Urology, Marmara University, School of Medicine, Istanbul, Türkiye.ORCID 0000-0003-0085-7680
Yiloren TanidirDepartment of Urology, Marmara University, School of Medicine, Istanbul, Türkiye.ORCID 0000-0003-1607-5819
Serap KetenciDepartment of Radiation Oncology, Unit of Radiation Health, Marmara University Pendik Training and Research Hospital, Istanbul, Türkiye.ORCID 0009-0004-5317-5469
Umut KutukogluDepartment of Urology, Marmara University, School of Medicine, Istanbul, Türkiye.ORCID 0000-0002-5043-5825
Dogancan DorucuDepartment of Urology, Marmara University, School of Medicine, Istanbul, Türkiye.ORCID 0000-0002-9714-3336
Huseyin CayirDepartment of Radiology, Unit of Radiation Health, Marmara University Pendik Training and Research Hospital, Istanbul, Türkiye.ORCID 0009-0003-1750-941X
Amelia PietropaoloYoung Academic Urologists, Endourology and Urolithiasis Working Party, European Association of Urology, Arnhem, Netherlands.ORCID 0000-0001-7631-3108
Esteban EmilianiYoung Academic Urologists, Endourology and Urolithiasis Working Party, European Association of Urology, Arnhem, Netherlands.ORCID 0000-0003-4488-0022
Bhaskar SomaniDepartment of Urology, NHS Foundation Trust, Southampton University Hospital, Southampton, UK.ORCID 0000-0002-6248-6478
Marmara University · TREuropean Association of Urology · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeRadiation exposure is affected by C-arm fluoroscopy device positioning during percutaneous renal puncture. Our aim was to compare the exposure of surgeon's lens, hand and chest with a fluoroscopy protocol replicated in different C-arm positions. MATERIALS AND

methodsA standardized fluoroscopy protocol was created using water-equivalent solid phantoms to replicate a surgeon and patient. 111 mGy radiation (360 s) was applied in standard fluoroscopy mode (91 kVp, 2.7 mA/mAs). Dosimeters were placed on lens, chest and hand of surgeon and patient phantom models. 7 different C-arm positions were created: 0°, mediolateral (ML) +90°, ML -90°, ML +30°, ML -15°, craniocaudal (CC) +30°, CC +15°. Measurements were evaluated separately for different positions.

resultsThe highest radiation exposure was measured on patient dosimeter (2.97 mSv). The highest exposure on surgeon was recorded on finger dosimeter in all C-arm positions; highest dose was recorded in ML +90° position (2.88 mSv). In finger dosimeters, lowest exposure was recorded in 0° position (0.51 mSv). The lowest exposure of all positions was measured in chest dosimeter in ML -90° position (0.24 mSv).

conclusionsIn positions where X-ray generator of the C-arm was facing towards the surgeon, radiation exposure measured in all dosimeters was higher compared to positions where the generator was facing away. The hand radiation exposure in all positions was higher than chest and lens. Special care must be taken to avoid facing the X-ray generator tube and hands should be as well-protected as chest and eyes with special protective gear.

Indexed as

Radiation ExposureUrolithiasisFluoroscopyHumansKidneyPuncturesPercutaneous nephrolithotomyRadiation exposure

Identifiers

PMID37668203
PMCPMC10482668
OpenAlexW4385559401

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.