Evidence map›Paper›PMID 37667965›Full record

ArticleOrthopaedic surgery2023

Finite Element Parametric Design of Hallux Valgus Orthosis Based on Orthogonal Analysis.

Zhi Tang, Yifei Wu, Wenlan Bao, Xiaoyan Chen, Die Zhang, Alexander Nikolaevich Korotkov, Weiming Zheng, Song Gu

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic surgery, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Zhi TangCollege of Mechanical Engineering, Donghua University, Shanghai, China.
Yifei WuCollege of Mechanical Engineering, Donghua University, Shanghai, China.
Wenlan BaoCollege of Mechanical Engineering, Donghua University, Shanghai, China.
Xiaoyan ChenCollege of Mechanical Engineering, Donghua University, Shanghai, China.
Die ZhangCollege of Mechanical Engineering, Donghua University, Shanghai, China.
Alexander Nikolaevich KorotkovInstitute of IT, Mechanical Engineering and Motor Vehicles, T.F. Gorbachev Kuzbass State Technical University, Kemerovo, Russia.
Weiming ZhengInstitute of IT, Mechanical Engineering and Motor Vehicles, T.F. Gorbachev Kuzbass State Technical University, Kemerovo, Russia.
Song GuTrauma Center, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Donghua University · CNKuzbass State Technical University · RUShanghai Jiao Tong University · CN

Funding

the National Natural Science Foundation of China 51775106
6 · The paper itself

Abstract

objectiveTo design appropriate orthosis for hallux valgus, a difficult foot condition that affects a quarter of the body's bones, we need to clarify the numerical biomechanical features, which have not been established in previous biomechanical studies. Therefore, we constructed a finite element model of the bunion foot to investigate the orthopaedic force compensation mechanism.

methodsA patient with moderate hallux valgus was recruited. CT imaging data in DICOM format were extracted for three-dimensional foot model reconstruction. In conjunction with the need for rapid design of bunion orthosis, a metatarsal force application sizing method based on an orthogonal test design was investigated. The orthogonal test design was used to obtain the hallux valgus angle (HVA) and the inter metatarsal angle (IMA) data for different force combinations. Based on the extreme difference analysis and analysis of variance of the test results, the influence of different force combinations on the bunion angle was quickly determined.

resultsThe results showed that the stress concentration occurred mainly in the first metatarsal bone. The distribution trend was in the medial and lateral middle of the bone and gradually decreased to the dorsal base of the bone body. The greatest stress occurs in the cartilage between the phalanges and metatarsals. In 25 groups of simulation experiments, HVA was reduced from 27.7° to 13°, and IMA was reduced from 12.5° to 7.3°.

conclusionApplying detailed orthopaedic force collocation to the first metatarsal column can effectively restore the mechanics and kinematics of hallux valgus, and provide a reference for the treatment of bunion valgus and the design of orthopaedic devices.

Indexed as

BunionHallux ValgusFinite Element AnalysisHumansOrthotic DevicesOsteotomyTreatment OutcomeBunionFinite Element SimulationOrthogonal Experimental DesignOrthosis

Identifiers

PMID37667965
PMCPMC10622271
OpenAlexW4386437918

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.