Evidence map›Paper›PMID 37667718›Full record

ArticleCureus2023

The Reliability of the Divergence Angle for Evaluating Rotational Implant Positioning in Medial Unicompartmental Knee Replacement.

Vincent Hardy, Marwan Garaud, Bandar M Hetaimish, Ramy Samargandi

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 77% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 2 countries.

Vincent HardyOrthopedic Surgery Department, Centre Hospitalier Régional Universitaire (CHRU) d'Orléans, Orléans, FRA.
Marwan GaraudOrthopedic Surgery Department, Centre Hospitalier Régional Universitaire (CHRU) d'Orléans, Orléans, FRA.
Bandar M HetaimishOrthopedic Surgery Department, Faculty of Medicine, University of Jeddah, Jeddah, SAU.
Ramy SamargandiOrthopedic Surgery Department, Faculty of Medicine, University of Jeddah, Jeddah, SAU.
Centre hospitalier régional d'Orléans · FRCentre Hospitalier Universitaire de Tours · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background Unicompartmental knee arthroplasty (UKA) is a highly effective surgical procedure used to treat patients with osteoarthritis affecting a single knee compartment. UKA has gained significant popularity, accompanied by an expansion of its surgical indications. This increasing trend can be attributed to the consistently excellent clinical outcomes associated with UKA, which rival those achieved with total knee arthroplasty (TKA). However, despite these advancements, implant rotation malposition remains a prevalent factor contributing to early failure in UKA cases. The aim of this study is to analyze the rotational positioning of femorotibial implants in UKA and to identify an appropriate angle formed by the femoral component and the tibial component using a newly described angle. Methods This was a retrospective study of patients' data of 40 medial UKA cases of 33 patients who were operated on in our hospital between October 1998 and March 2019. The study introduces a new angle called the "divergence angle." This angle is formed between the lateral portion of the femoral component and the lateral part of the tibial component, as measured on a patellofemoral Merchant view at 30 degrees of knee flexion. The divergence angle was evaluated through radiographic assessment by two independent reviewers. Results According to statistical analysis, the divergence angle was highly reliable with both intra- and inter-observer reproducibility. Intra-observer reproducibility was excellent with an intra-class correlation coefficient (ICC) between 0.901 and 0.933 (p < 0.001). The inter-observer reproducibility was excellent with an ICC of 0.92 (p < 0.001). The Gaussian curve confirmed the normal distribution of the divergence angle values with moderate dispersion of values. The majority of the angles of divergence (85%) measured between the femoral and tibial components were less than 10 degrees (n = 34), with a mean angle of 6.3 ± 4.5°. Conclusion The divergence angle between the femoral and tibial components, measured at 30 degrees of knee flexion using the Merchant view, is an easily accessible, reliable, and reproducible method. This technique enables the assessment of the optimal rotational positioning of implants in medial UKA.

Indexed as

divergence angleknee osteoarthritisknee surgeryrotational positioningunicompramental knee arthroplasty

Identifiers

PMID37667718
PMCPMC10475295
OpenAlexW4385576088

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.