Evidence map›Paper›PMID 37662581›Full record

ArticleEuropean heart journal. Case reports2023

Simple bailout technique using a snare catheter for wire withdrawal during balloon-expandable transcatheter aortic valve implantation: a case report.

Masaki Tsuda, Yasuyuki Egami, Shodai Kawanami, Masami Nishino

Open access · goldAbstract readCase Reports
In one paragraph

Article in European heart journal. Case reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Masaki TsudaDivision of Cardiology, Osaka Rosai Hospital, 1179-3 Nagasone-cho, Osaka, Sakai 591-8025, Japan.ORCID https://orcid.org/0000-0003-0370-7047
Yasuyuki EgamiDivision of Cardiology, Osaka Rosai Hospital, 1179-3 Nagasone-cho, Osaka, Sakai 591-8025, Japan.ORCID https://orcid.org/0000-0001-9728-6524
Shodai KawanamiDivision of Cardiology, Osaka Rosai Hospital, 1179-3 Nagasone-cho, Osaka, Sakai 591-8025, Japan.
Masami NishinoDivision of Cardiology, Osaka Rosai Hospital, 1179-3 Nagasone-cho, Osaka, Sakai 591-8025, Japan.ORCID https://orcid.org/0000-0003-0309-7023
Osaka Rosai Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: In transcatheter aortic valve implantation (TAVI) using a SAPIEN3 balloon-expandable valve (S3), wire withdrawal from the left ventricle (LV) during the procedure before deployment can induce vascular injury in the access site or require surgical treatment when an S3 removal is attempted. We present a successful case of bailout from this situation safely with a minimally invasive technique using a 6-F snare catheter (SC). Case summary: An 86-year-old woman with severe aortic stenosis underwent trans-femoral TAVI using an S3 under conscious sedation. After a pre-shaped wire was inserted into the LV from the right femoral artery, the LV wire was accidentally withdrawn completely from the LV before deployment. Wire re-insertion using a soft straight wire through the tip lumen of the S3 was hindered because the wire orientation was uncontrollable. Hence, we used a 6-F SC to control the wire direction by changing the orientation of the S3. Catching the tip of the S3 with an SC at the ascending aorta enabled us to control the wire direction, and wire re-insertion in the LV with the soft wire was successful. Furthermore, the SC worked well in advancing the S3 through the aortic valve to enhance co-axiality without aortic root injury. The S3 was successfully advanced through the aortic valve and implanted at an optimal position without complications. Discussion: Our simple technique using a 6-F SC is technically effective, feasible, and minimally invasive and can be an option for bailout from accidental LV wire withdrawal during balloon-expandable valve TAVI.

Indexed as

BailoutBalloon-expandable valveCase reportSnare catheterTranscatheter aortic valve implantation

Identifiers

PMID37662581
PMCPMC10473850
OpenAlexW4385987297

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.