Evidence map›Paper›PMID 37661241›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2024

Does the type of medial plate fixation matter for supplemental fixation of distal femur fractures manage with a lateral pre-contoured locked plate? A Biomechanical study.

Sebastián Pereira, Fernando Bidolegui, Germán Garabano, Cesar Angel Pesciallo, Vincenzo Giordano, Robinson Estevez Pires, José Ricardo Mariolani, William Dias Belangero

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 6 institutions in 3 countries.

Sebastián PereiraServicio de Ortopedia y Traumatologia, Sanatorio San Lucas, Belgrano 369, B1642, San Isidro, Buenos Aires, Argentina. dr.psebastianpereira@gmail.com.ORCID http://orcid.org/0000-0001-9475-3158
Fernando BidoleguiServicio de Ortopedia y Traumatologia, Hospital Sirio-Libanes, Campana 4658, C1419, Buenos Aires, Argentina.
Germán GarabanoServicio de Ortopedia y Traumatologia, Hospital Británico de Buenos Aires, Perdriel 74, C1280 AEB, Buenos Aires, Argentina.
Cesar Angel PescialloServicio de Ortopedia y Traumatologia, Hospital Británico de Buenos Aires, Perdriel 74, C1280 AEB, Buenos Aires, Argentina.
Vincenzo GiordanoServiço de Ortopedia e Traumatologia Prof. Nova Monteiro, Hospital Municipal Miguel Couto, Rio de Janeiro, Brazil.
Robinson Estevez PiresDepartamento do Aparelho Locomotor, Universidade Federal de Minas Gerais, Belo Horizonte, Brazil.
José Ricardo MariolaniBiomaterials Laboratory in Orthopedics (LABIMO), Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, SP, Brazil.
William Dias BelangeroBiomaterials Laboratory in Orthopedics (LABIMO), Faculty of Medical Sciences, University of Campinas (UNICAMP), Campinas, SP, Brazil.
Hospital Británico de Buenos Aires · ARUniversidade Estadual de Campinas (UNICAMP) · BRHospital Geral de Bonsucesso · BRSanatorio Otamendi y Miroli · ARSANE Mental Health Charity · GBUniversidade Federal de Minas Gerais · BR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionFixation of distal femur fractures with a lateral pre-contoured locking plate provides stable fixation and is the standard treatment in most cases, allowing early range of motion with a high rate of union. However, in situations, the stability achieved with the lateral plate alone may be insufficient, predisposing to fixation failure. The objective of the study was to compare, in synthetic bone models, the biomechanical behaviour of the fixation with a distal femur lateral pre-contoured locking plate solely and associated with a 3.5 mm proximal humeral locking plate applied upside down or a 4.5 mm helical locking compression plate on the medial side. MATERIAL AND

methodsA total of 15 solid synthetic left femur samples were used. A metaphysical defect at the level of the medial cortex was simulated. The samples were randomly distributed into three groups equally. All groups received a 4.5/5.0 mm single lateral 9-hole distal femur lateral pre-contoured locking plate. Group 1 had no supplementary plate. Group 2 received a supplementary 6-hole 3.5 mm proximal humeral locking plate and Group 3 received a supplementary 4.5/5.0 mm helical 14-hole narrow locking compression plate.

resultsBoth supplementary plate types used in groups 2 and 3 contributed to increase the apparent stiffness of the construct, but pairwise comparison showed statically significant difference only between group 1 and 3. No significant difference was observed between groups 2 and 3.

conclusionBoth supplementary plates might be considered for improving the fixation in distal femur fracture in selected cases.

Indexed as

Femoral FracturesFemoral Fractures, DistalBiomechanical PhenomenaBone PlatesFemurFracture Fixation, InternalHumansDistal femur fractureDual platingHelical plate

Identifiers

PMID37661241
OpenAlexW4386402306

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked