Evidence map›Paper›PMID 37660271›Full record

ArticleAdvanced healthcare materials2023

Magnetic-Responsive Carbon Nanotubes Composite Scaffolds for Chondrogenic Tissue Engineering.

Muthusamy Saranya, Aldeliane M da Silva, Hanna Karjalainen, Geir Klinkenberg, Ruth Schmid, Birgitte McDonagh, Peter P Molesworth, Margrét S Sigfúsdóttir, Ane Marit Wågbø, Susana G Santos and 11 more

Abstract read
In one paragraph

Article in Advanced healthcare materials, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Engineering Stimuli-Responsive Materials for Precision Medicine.Small (Weinheim an der Bergstrasse, Germany) · 2025
    Review
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

21 authors.

Muthusamy SaranyaMicroelectronic Research Unit, University of Oulu, Oulu, 90570, Finland.
Aldeliane M da SilvaMicroelectronic Research Unit, University of Oulu, Oulu, 90570, Finland.
Hanna KarjalainenResearch Unit of Health Science and Technology, University of Oulu, Oulu, 90220, Finland.
Geir KlinkenbergDepartment of Biotechnology and Nanomedicine SINTEF Industry, Trondheim, 7030, Norway.
Ruth SchmidDepartment of Biotechnology and Nanomedicine SINTEF Industry, Trondheim, 7030, Norway.
Birgitte McDonaghDepartment of Biotechnology and Nanomedicine SINTEF Industry, Trondheim, 7030, Norway.
Peter P MolesworthDepartment of Biotechnology and Nanomedicine SINTEF Industry, Trondheim, 7030, Norway.
Margrét S SigfúsdóttirDepartment of Biotechnology and Nanomedicine SINTEF Industry, Trondheim, 7030, Norway.
Ane Marit WågbøDepartment of Biotechnology and Nanomedicine SINTEF Industry, Trondheim, 7030, Norway.
Susana G SantosInstituto Nacional de Engenharia Biomédica, Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Porto, 4200-135, Portugal.
Cristiana CoutoInstituto Nacional de Engenharia Biomédica, Instituto de Investigação e Inovação em Saúde, Universidade do Porto, Porto, 4200-135, Portugal.
Ville-Pauli KarjalainenResearch Unit of Health Science and Technology, University of Oulu, Oulu, 90220, Finland.
Shuvashis Das GuptaResearch Unit of Health Science and Technology, University of Oulu, Oulu, 90220, Finland.
Topias JärvinenMicroelectronic Research Unit, University of Oulu, Oulu, 90570, Finland.
Luisa de RoyInstitute of Orthopedic Research and Biomechanics, Center for Trauma Research, Ulm University Medical Center Ulm, 89081, Ulm, Germany.
Andreas M SeitzInstitute of Orthopedic Research and Biomechanics, Center for Trauma Research, Ulm University Medical Center Ulm, 89081, Ulm, Germany.
Mikko FinniläResearch Unit of Health Science and Technology, University of Oulu, Oulu, 90220, Finland.
Simo SaarakkalaResearch Unit of Health Science and Technology, University of Oulu, Oulu, 90220, Finland.
Anne Marie HaaparantaAskel Healthcare Ltd., Helsinki, 00530, Finland.
Lauriane JanssenMicroelectronic Research Unit, University of Oulu, Oulu, 90570, Finland.
Gabriela S LoriteMicroelectronic Research Unit, University of Oulu, Oulu, 90570, Finland.ORCID 0000-0002-6530-5281

Funding

Horizon 2020 research and innovation programme 814558Material Analysis Center at the University of OuluResearch Council of Finland (former Academy of Finland) #317437Research Council of Finland (former Academy of Finland) #320090
6 · The paper itself

Abstract

The demand for engineered scaffolds capable of delivering multiple cues to cells continues to grow as the interplay between cell fate with microenvironmental and external cues is revealed. Emphasis has been given to develop stimuli-responsive scaffolds. These scaffolds are designed to sense an external stimulus triggering a specific response (e.g., change in the microenvironment, release therapeutics, etc.) and then initiate/modulate a desired biofunction. Here, magnetic-responsive carboxylated multi-walled carbon nanotubes (cMWCNTs) are integrated into 3D collagen/polylactic acid (PLA) scaffold via a reproducible filtration-based method. The integrity and biomechanical performance of the collagen/PLA scaffolds are preserved after cMWCNT integration. In vitro safety assessment of cMWCNT/collagen/PLA scaffolds shows neither cytotoxicity effects nor macrophage pro-inflammatory response, supporting further in vitro studies. The cMWCNT/collagen/PLA scaffolds enhance chondrocytes metabolic activity while maintaining high cell viability and extracellular matrix (i.e., type II collagen and aggrecan) production. Comprehensive in vitro study applying static and pulsed magnetic field on seeded scaffolds shows no specific cell response in dependence with the applied field. This result is independent of the presence or absence of cMWCNT into the collagen/PLA scaffolds. Taken together, these findings provide additional evidence of the benefits to exploit the CNTs outstanding properties in the design of stimuli-responsive scaffolds.

Indexed as

Nanotubes, CarbonTissue EngineeringCollagenMagnetic PhenomenaPolyestersTissue ScaffoldsCollagenNanotubes, CarbonPolyesterscarbon nanotubescartilagemagnetic stimulationsmart nanomaterialsstimuli-responsive scaffoldtissue engineering

Identifiers

PMID37660271
PMCPMC11468560

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.