Evidence map›Paper›PMID 37658855›Full record

ArticleArchives of orthopaedic and trauma surgery2024

Precontoured dynamic compression plate using patient-specific 3D-printed models in minimally invasive surgical technique for midshaft clavicle fractures.

Puripun Jirangkul, Natcha Lorsuwannarat, Nutthapong Wanichjaroen

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Puripun JirangkulDepartment of Orthopaedics, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand. dr.puripun@gmail.com.ORCID http://orcid.org/0000-0003-0390-7655
Natcha LorsuwannaratDepartment of Anatomy, Phramongkutklao College of Medicine, Bangkok, Thailand.
Nutthapong WanichjaroenDepartment of Plastic Surgery, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand.
Phramongkutklao Hospital · TH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThis study introduced a novel approach for the treatment of midshaft clavicle fractures, utilizing patient-specific 3D-printed models for accurate preoperative contouring of dynamic compression plates (DCPs) and an alternative minimally invasive plate osteosynthesis (MIPO) technique with precontoured DCPs through small vertical separated incisions. PATIENT AND

methodsMirror image 3D clavicular models were reproduced from 40 patients with acute displaced midshaft clavicle fractures who underwent MIPO using precontoured DCPs inserted through small, vertical separated incisions. Exclusion criteria included patients with open fractures, pathological fractures, ipsilateral limb injury, skeletal immature patients, and those who had previous clavicle fractures or surgery. Postoperative evaluation was conducted using clinical and radiographic review. The Constant-Murley and American Shoulder and Elbow Surgeons Shoulder Scores were used for clinical evaluations, and the Patient and Observer Scar Assessment Scale was used to assess surgical scars.

resultsThe average time to union of all fractures was 12.88 weeks (range, 8-15) without loss of reduction. The patient-specific precontoured DCPs fitted well in all cases, with fracture consolidation and minimal three cortical sides connecting the fracture fragment. No hardware prominence and skin complications occurred, and clinical evaluation showed no existing difference compared with the contralateral sides. The average Constant-Murley and American Shoulder and Elbow Surgeons Shoulder Scores were 96.33 ± 3.66 and 93.26 ± 5.15, respectively. Two patients requested their implant removal, and scar qualities were satisfactory.

conclusionsOur study demonstrated that the use of a patient-specific precontoured DCP, in combination with 3D printing technology, provides accurate preoperative planning, effective fracture reduction, and improved postoperative outcomes in displaced midshaft clavicle fractures. The MIPO with a patient-specific precontoured DCP through separated vertical incisions along the Langer's lines appears to be a promising option, regarding appearance, avoiding associated complications, and obviating the need for reoperation. These results suggest that this technique has merit and can be a viable option for the treatment of midshaft clavicle fractures.

Indexed as

Fractures, BoneFractures, OpenBone PlatesCicatrixClavicleFracture Fixation, InternalFracture HealingHumansMinimally Invasive Surgical ProceduresPrinting, Three-DimensionalRetrospective StudiesTreatment Outcome3D printingClavicle fractureDynamic compression plateMIPOPrecontoured plate

Identifiers

PMID37658855
OpenAlexW4386390944

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.