Evidence map›Paper›PMID 37658158›Full record

ArticleScientific reports2023

A highly accurate quantum optimization algorithm for CT image reconstruction based on sinogram patterns.

Kyungtaek Jun

Erratum issuedAbstract read
In one paragraph

Article in Scientific reports, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

1 author.

Kyungtaek JunQuantum Research Center, QTomo, Busan, South Korea. ktfriends@gmail.com.

Funding

Ministry of Science and ICT, South Korea 2020M3H3A111036513
6 · The paper itself

Abstract

Computed tomography (CT) has been developed as a nondestructive technique for observing minute internal images in samples. It has been difficult to obtain photorealistic (clean or clear) CT images due to various unwanted artifacts generated during the CT scanning process, along with the limitations of back-projection algorithms. Recently, an iterative optimization algorithm has been developed that uses an entire sinogram to reduce errors caused by artifacts. In this paper, we introduce a new quantum algorithm for reconstructing CT images. This algorithm can be used with any type of light source as long as the projection is defined. Assuming an experimental sinogram produced by a Radon transform, to find the CT image of this sinogram, we express the CT image as a combination of qubits. After acquiring the Radon transform of the undetermined CT image, we combine the actual sinogram and the optimized qubits. The global energy optimization value used here can determine the value of qubits through a gate model quantum computer or quantum annealer. In particular, the new algorithm can also be used for cone-beam CT image reconstruction and for medical imaging.

Identifiers

PMID37658158
PMCPMC10474150

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.