Evidence map›Paper›PMID 37655240›Full record

ArticleOrthopaedic journal of sports medicine2023

Best-Fit Circle for the Replication of Humeral Head Anatomy in Total Shoulder Arthroplasty.

Kyungil Kim, Sunghun Ju, Jinyoung Jeong

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Kyungil KimDepartment of Orthopedic Surgery, Wonkwang University Sanbon Hospital, Gunpo, Republic of Korea.
Sunghun JuDepartment of Orthopedic Surgery, St Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Jinyoung JeongDepartment of Orthopedic Surgery, St Vincent's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.
Wonkwang University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Anatomic restoration of the humeral head is critical for successful shoulder replacement. Accurate measurements of the humeral head are essential for anatomic substitution. Purpose: To evaluate whether a best-fit circle of the humeral head, as determined from different projections of plain radiographs, can predict the humeral head implant size for either the left or right shoulder. Study Design: Descriptive laboratory study. Methods: Bilateral shoulder radiographs of 200 patients without arthropathy or other abnormal findings of the humeral head were evaluated. The best-fit circle was obtained based on 3 points: the medial and lateral endpoints of the anatomic neck and the lateral cortex below the greater tuberosity. This circle was drawn on 5 different radiographic projections (shoulder anteroposterior [AP], glenoid AP, outlet, axillary, and 30° caudal tilt) of the left and right shoulders of each patient, and the radius of each circle was measured. Agreement in the best-fit circle radius between the left and right shoulders was statistically analyzed using the intraclass correlation coefficient (ICC). There were 2 independent blinded observers who performed each measurement twice to evaluate inter- and intraobserver reliability. Results: Overall agreement in the radius between the right and left shoulders was excellent (all ICCs ≥0.990). The ICCs according to the radiographic view were 0.990 (95% CI, 0.986-0.993) for shoulder AP, 0.992 (95% CI, 0.989-0.995) for glenoid AP, 0.996 (95% CI, 0.994-0.997) for outlet, 0.994 (95% CI, 0.991-0.996) for axillary, and 0.993 (95% CI, 0.990-0.995) for 30° caudal tilt. Interobserver ICCs demonstrated a high level of precision: 0.987 (95% CI, 0.978-0.993) for shoulder AP, 0.986 (95% CI, 0.974-0.992) for glenoid AP, 0.974 (95% CI, 0.954-0.985) for outlet, 0.991 (95% CI, 0.984-0.995) for axillary, and 0.987 (95% CI, 0.977-0.993) for 30° caudal tilt. Intraobserver ICCs demonstrated excellent test-retest reliability: 0.983 (95% CI, 0.970-0.991) for shoulder AP, 0.989 (95% CI, 0.980-0.994) for glenoid AP, 0.987 (95% CI, 0.978-0.993) for outlet, 0.985 (95% CI, 0.973-0.991) for axillary, and 0.970 (95% CI, 0.947-0.983) for 30° caudal tilt. Conclusion: The best-fit circle to calculate the ideal size of a humeral head implant was able to be determined from different projections of plain radiographs. Clinical Relevance: Anatomic restoration of a deformed humeral head can be achieved using the best-fit circle of the contralateral humeral head as obtained from plain radiographs. This method can facilitate preoperative planning and postoperative evaluation in the anatomic restoration of the shoulder to avoid the problems of overstuffing.

Indexed as

anatomicarthroplastycirclehumeral headplain radiographshoulder

Identifiers

PMID37655240
PMCPMC10467389
OpenAlexW4386258455

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.