Evidence map›Paper›PMID 37653275›Full record

ArticleJournal of anesthesia2023

Effects of the attachment method of the stimulating electrodes Nihon-Kohden NM-345Y™ and changes in forearm position on stimulus current values during calibration in electromyography-based neuromuscular monitoring: a single-center experimental study.

Madoka Makino, Shohei Kaneko, Shuntaro Sato, Yurika Kawazoe, Taiga Ichinomiya, Hiroaki Murata, Osamu Yoshitomi, Tetsuya Hara

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of anesthesia, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Madoka MakinoDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Shohei KanekoDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan. s-kaneko@nagasaki-u.ac.jp.ORCID 0000-0002-0156-4559
Shuntaro SatoClinical Research Center, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Yurika KawazoeClinical Research Center, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Taiga IchinomiyaDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Hiroaki MurataDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Osamu YoshitomiDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Tetsuya HaraDepartment of Anesthesiology and Intensive Care Medicine, Nagasaki University Graduate School of Biomedical Sciences, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe traditionally recommended method for attaching electromyography (EMG) electrodes (NM-345Y™) during EMG-based neuromuscular monitoring developed by Nihon-Kohden may decrease the monitoring accuracy when forearm limb position changes. This study investigated methods for attaching stimulating electrodes that maintained stable EMG-based neuromuscular monitoring accuracy, regardless of forearm limb position changes.

methodsThis single-center experimental study recruited 28 healthy adults from October 2022 to December 2022. The NM-345Y™ was attached to the forearm using three patterns: Pattern N, electrodes attached according to the attachment pattern recommended by Nihon-Kohden; Pattern U, electrodes attached along the ulnar nerve identified using an ultrasound device; Pattern C, electrodes attached where the ulnar nerve crosses the line connecting the centers of the anode and cathode of the stimulating electrodes. The stimulus current values during calibration were measured at three forearm positions for each attachment pattern: supination 90 degrees; pronation 0 degrees; pronation 90 degrees. The differences in stimulus current values caused by forearm position changes were calculated as the difference between values at supination 90 degrees and pronation 0 degrees and between values at supination 90 degrees and pronation 90 degrees.

resultsPattern C showed significantly smaller differences than Pattern N between the stimulus current values at supination 90 degrees and pronation 0 degrees (p = 0.018) and between the stimulus current values at supination 90 degrees and pronation 90 degrees (p = 0.008).

conclusionCrossing the ulnar nerve with the line connecting the anode and cathode of the stimulating electrodes may stabilize EMG-based neuromuscular monitoring accuracy.

Indexed as

ForearmNeuromuscular MonitoringAdultCalibrationElectromyographyHumansUlnar NerveElectromyographyForearm positionNeuromuscular blocking agentsNeuromuscular monitoringStimulating electrodes attachmentStimulus current value

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked