Evidence map›Paper›PMID 37651144›Full record

Trial reportJAMA network open2023

Effect of Metrics-Based Simulation Training to Proficiency on Procedure Quality and Errors Among Novice Cardiac Device Implanters: The IMPROF Randomized Trial.

Jorio Mascheroni, Martin Stockburger, Ashish Patwala, Lluís Mont, Archana Rao, Hartwig Retzlaff, Christophe Garweg, Tom Verbelen, Anthony G Gallagher

Registry-linked trialOpen access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in JAMA network open, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05952908 (Effect of Quality Assured Simulation Training on Cardiac Device Implanter Skills), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05952908 nacompletednot on this map

Effect of Quality Assured Simulation Training on Cardiac Device Implanter Skills

TypeinterventionalSponsorJorio MascheroniRan2022 to 2022Enrolled32ConditionsKnowledge, Attitudes, PracticeArmsProficiency-Based Progression simulation training, Traditional simulation training
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 9 citations in OpenAlex.

  1. Training Programs for Thyroid Biopsy and Ablation: A Systematic Review.Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists · 2026
    Pooled it
  2. Trial
  3. Surgical skill simulation training to proficiency reduces procedural errors among novice cardiac device implanters: a randomized study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Trial
  4. Article
  5. Article
  6. Article
  7. Digitally assisted learning in cardiac electrophysiology and cardiac implantable electronic devices: a Scientific Statement of the European Heart Rhythm Association of the ESC.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Review
  8. Article
  9. Utilization of and perceived need for simulators in clinical electrophysiology: results from an EHRA physician survey.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 7 institutions in 5 countries.

Jorio MascheroniDepartment of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
Martin StockburgerDepartment of Cardiology and Internal Medicine, Havelland Kliniken, Nauen, Germany.
Ashish PatwalaDepartment of Cardiology, University Hospital of North Midlands, Stoke-on-Trent, United Kingdom.
Lluís MontDepartment of Cardiology, Hospital Clinic, Universitat de Barcelona, Barcelona, Catalonia, Spain.
Archana RaoDepartment of Cardiology, Liverpool Heart and Chest Hospital, Liverpool, United Kingdom.
Hartwig RetzlaffTraining Concept Consulting, Groebenzell, Germany.
Christophe GarwegDepartment of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
Tom VerbelenDepartment of Cardiovascular Sciences, KU Leuven, Leuven, Belgium.
Anthony G GallagherOrsi Academy, Melle, Belgium.
KU Leuven · BECharité - Universitätsmedizin Berlin · DELiverpool Heart and Chest Hospital · GBORSI Academy · BEUniversitair Ziekenhuis Leuven · BEUniversitat de Barcelona · ESUniversity Hospitals of North Midlands NHS Trust · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: In cardiac device implant training, there is no common system to objectively assess trainees' ability to perform tasks at predetermined performance levels before in vivo practice; therefore, patients are potentially exposed to risks related to operators' early learning curve. Objective: To assess the effect on implant performance quality of novel metrics-based simulation training to proficiency (proficiency-based progression [PBP]) vs traditional simulation-based training (SBT). Design, Setting, and Participants: In this prospective randomized trial, conducted between March 8, 2022 and November 24, 2022, novice implanters were randomized (blinded) 1:1 to participate in an SBT curriculum (procedural knowledge e-learning and in-person simulation training) at an international skills training center, with proficiency demonstration requirements at each training stage for advancing (PBP approach) or without the requirements. Ultimately, trainees performed a cardiac resynchronization therapy (CRT) implant using virtual reality simulation. The procedure was video-recorded and subsequently scored using previously validated metrics by 2 independent assessors blinded to group. Physicians who had already implanted more than 20 pacemakers or defibrillators and fewer than 200 CRT systems as the first operator were eligible. Thirty-two implanters from 10 countries voluntarily enrolled in the training program and were randomized; 30 (15 per group) started and completed training. Data analysis was performed from November 27 to December 22, 2022. Intervention: Training with PBP vs SBT. Main Outcome and Measures: The primary outcome comprised 4 objectively assessed performance metrics derived from the video-recordings: number of procedural steps completed, errors, critical errors, and all errors combined. Results: Baseline experience of the 30 participants (19 [63%] male; mean [SD] number of years in implant practice, 2.0 [1.8]; median [IQR] number of implanted pacemakers or defibrillators, 47.5 [30.0-115.0]; median [IQR] number of implanted CRT systems, 3.0 [1.25-10.0]) was similar between study groups. Compared with the SBT group, the PBP group completed 27% more procedural steps (median [IQR], 31 [30-32] vs 24 [22-27]; P < .001) and made 73% fewer errors (median [IQR], 2 [1-3] vs 7 [5-8]; P < .001), 84% fewer critical errors (median [IQR], 1 [0-1] vs 3 [3-5]; P < .001), and 77% fewer all errors combined (errors plus critical errors) (median [IQR], 3 [1-3] vs 11 [8-12]; P < .001); 14 of the 15 PBP trainees (93%) demonstrated the predefined target performance level vs 0 of the 15 SBT trainees. Conclusions and Relevance: In this randomized trial, the PBP approach to novice implanter training generated superior objectively assessed performance vs SBT. If implemented broadly and systematically, PBP training may ensure safe and effective performance standards before trainees proceed to (supervised) in vivo practice. Future studies are needed to verify implications on procedure-related patient complications. Trial Registration: ClinicalTrials.gov Identifier: NCT05952908.

Indexed as

Cardiac Resynchronization TherapyDefibrillators, ImplantableBenchmarkingCurriculumFemaleHumansMaleProspective Studies

Identifiers

PMID37651144
PMCPMC10472192
OpenAlexW4386305668

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.