ArticleBMC musculoskeletal disorders2023
Biomechanical properties of lumbar vertebral ring apophysis cage under endplate injury: a finite element analysis.
Article in BMC musculoskeletal disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Article
- Impact of endplate-graft geometric matching on cage subsidence following stand-alone lateral lumbar interbody fusion: a finite element analysis.BMC musculoskeletal disorders · 2026Article
- Utilizing MRI and CT to identify risk factors associated with cage subsidence.European journal of medical research · 2025Article
- Trabecular Bone Remodeling after Lateral Lumbar Interbody Fusion: Indirect Findings for Stress Transmission between Vertebrae after Spinal Fusion Surgery.Spine surgery and related research · 2025Article
- Finite Element Analysis of Stress Distribution and Range of Motion in Discogenic Back Pain.Neurospine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThis study aimed to compare the biomechanical properties of lumbar interbody fusion involving two types of cages. The study evaluated the effectiveness of the cage spanning the ring apophysis, regardless of the endplate's integrity.
methodsA finite element model of the normal spine was established and validated in this study. The validated model was then utilized to simulate Lateral Lumbar Interbody Fusion (LLIF) with posterior pedicle screw fixation without posterior osteotomy. Two models of interbody fusion cage were placed at the L4/5 level, and the destruction of the bony endplate caused by curetting the cartilaginous endplate during surgery was simulated. Four models were established, including Model 1 with an intact endplate and long cage spanning the ring apophysis, Model 2 with endplate decortication and long cage spanning the ring apophysis, Model 3 with an intact endplate and short cage, and Model 4 with endplate decortication and short cage. Analyzed were the ROM of the fixed and adjacent segments, screw rod system stress, interface stress between cage and L5 endplate, trabecular bone stress on the upper surface of L5, and intervertebral disc pressure (IDP) of adjacent segments.
resultsThere were no significant differences in ROM and IDP between adjacent segments in each postoperative model. In the short cage model, the range of motion (ROM), contact pressure between the cage and endplate, stress in L5 cancellous bone, and stress in the screw-rod system all exhibited an increase ranging from 0.4% to 79.9%, 252.9% to 526.9%, 27.3% to 133.3%, and 11.4% to 107%, respectively. This trend was further amplified when the endplate was damaged, resulting in a maximum increase of 88.6%, 676.1%, 516.6%, and 109.3%, respectively. Regardless of the integrity of the endplate, the long cage provided greater support strength compared to the short cage.
conclusionsCaution should be exercised during endplate preparation and cage placement to maintain the endplate's integrity. Based on preoperative X-ray evaluation, the selection of a cage that exceeds the width of the pedicle by at least 5 mm (ensuring complete coverage of the vertebral ring) has demonstrated remarkable biomechanical performance in lateral lumbar interbody fusion procedures. By opting for such a cage, we expect a reduced occurrence of complications, including cage subsidence, internal fixation system failure, and rod fracture.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials